Advantages of using a modified orthogonal sampling configuration originally designed for LC-ESI-MS to couple CE and MS for the determination of antioxidant phenolic compounds found in virgin olive oil

被引:14
作者
Berzas Nevado, Juan Jose [1 ]
Castaneda Penalvo, Gregorio [1 ]
Rodriguez Robledo, Virginia [1 ]
机构
[1] Univ Castilla La Mancha, Dept Analyt Chem & Food Technol, E-13071 Ciudad Real, Spain
关键词
Antioxidants; CE-ESI-MS; Electrospray source; Orthogonal coupling; Phenolic acids; ELECTROPHORESIS-MASS-SPECTROMETRY; ASSISTED-LASER-DESORPTION/IONIZATION; CAPILLARY-ZONE-ELECTROPHORESIS; LIQUID-JUNCTION; SPRAY INTERFACE; SEPARATIONS; INSTRUMENTATION; TOOL;
D O I
10.1016/j.talanta.2010.05.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A ThermoFinnigan sheath liquid flow capillary electrophoresis-mass spectrometry system designed for coupling via a co-axial interface was coupled through an adapted via an alternative, commercially available interface for orthogonal sampling. The affordable, reversible structural alterations made in the commercial LC-MS interface resulted in improved analytical performance. The results of a conventional capillary electrophoresis (CE) method using a commercial co-axial source to determine antioxidant phenolic acids present in virgin olive oil, were compared with those obtained by using a modified orthogonal sampling position. In both cases, separations were done using a 10 mM ammonium acetate/ammonium hydroxide buffer solution at pH 10.0 and a constant applied voltage of 25 kV. The operating variables for the mass spectrometry interface were re-optimized for the modified orthogonal orientation. This allowed the sheath liquid, sheath gas flow rates and capillary voltage to be lowered with respect to the co-axial coupling configuration. In addition, the orthogonal sampling position provided a higher selectivity by effect of ion sampling excluding larger droplets with an increased momentum along the axis which were drained through the sink at the bottom of the ion source. Also, the new configuration facilitated sample ionization, improved electrospray stability and led to stronger signals as a result. The new system was validated in terms of precision (repeatability), linearity, and limits of detection and quantification. A comparison of the validation data with the results previously obtained by using a commercial co-axial configuration revealed the adapted orthogonal sampling position to provide better repeatability in both migration times and relative peak areas (<1% and 7% respectively with n = 15 replicates), a good linear range (with levels in the microgram-per-litre region) and lower limits of detection especially for the compounds detected with the lowest sensitivity when co-axial ESI was used, as HFA, GEN, FER and VAN finding LOD among 24-3.0 mu g L(-1) respectively. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 49 条
  • [1] New CE-ESI-MS analytical method for the separation, identification and quantification of seven phenolic acids including three isomer compounds in virgin olive oil
    Berzas Nevado, Juan Jose
    Castaneda Penalvo, Gregorio
    Rodriguez Robledo, Virginia
    Vargas Martinez, Gabriela
    [J]. TALANTA, 2009, 79 (05) : 1238 - 1246
  • [2] ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY
    BRUINS, AP
    COVEY, TR
    HENION, JD
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2642 - 2646
  • [3] Laser vaporization/ionization interface for capillary electrophoresis time-of-flight mass spectrometry
    Chang, SY
    Yeung, ES
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2251 - 2257
  • [4] An introduction to quadrupole-time-of-flight mass spectrometry
    Chernushevich, IV
    Loboda, AV
    Thomson, BA
    [J]. JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08): : 849 - 865
  • [5] Covas MI, 2001, THERAPIE, V56, P607
  • [6] Foret F, 2002, PROTEOMICS, V2, P360, DOI 10.1002/1615-9861(200204)2:4<360::AID-PROT360>3.0.CO
  • [7] 2-Y
  • [8] SMALL-VOLUME AND LOW FLOW-RATE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF AQUEOUS SAMPLES
    GALE, DC
    SMITH, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (11) : 1017 - 1021
  • [9] The effects of harvest and extraction methods on the antioxidant content (phenolics, α-tocopherol, and β-carotene) in virgin olive oil
    Gimeno, E
    Castellote, AI
    Lamuela-Raventós, RM
    De la Torre, MC
    López-Sabater, MC
    [J]. FOOD CHEMISTRY, 2002, 78 (02) : 207 - 211
  • [10] Interfacing matrix-assisted laser desorption/ionization mass spectrometry with column and planar separations
    Gusev, AI
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7): : 691 - 700