Sol-gel open tubular ODS columns with reversed eleotroosmotic flow for capillary electrochromatography

被引:91
作者
Hayes, JD [1 ]
Malik, A [1 ]
机构
[1] Univ S Florida, Dept Chem, Tampa, FL 33620 USA
关键词
D O I
10.1021/ac000817a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sol-gel chemistry was successfully used for the fabrication of open tubular columns with surface-bonded octadecylsilane (ODS) stationary-phase coating for capillary electrochromatography (OT-CEC). Following column preparations, a series of experiments were performed to investigate the performance of the sol-gel coated ODS columns in OT-CEC. The incorporation of N-octadecyldimethyl[3-(trimethoxysilyl)propyl]ammonium chloride as one of the sol-gel precursors played an important role in the electrochromatographic performance of the prepared columns. This chemical reagent possesses a chromatographically favorable, bonded ODS moiety, in conjunction with three methoxy groups allowing for sol-gel reactivity. In addition, a positively charged nitrogen atom is present in the molecular structure of this reagent and provides a positively charged capillary surface responsible for the reversed electroosmotic now (EOF) in the columns during CEC operation. Comparative studies involving the EOF within such sol-gel ODS coated and uncoated capillaries were performed using acetonitrile and methanol as the organic modifiers hi the mobile phase. The use of a deactivating reagent, phenyldimethylsilane, in the sol-gel solution was evaluated. Efficiency values of over 400 000 theoretical plates per meter were achieved in CEC on a 63 cm x 25 mum i.d, sol-gel ODS open tubular column. Test mixtures of polycyclic aromatic hydrocarbons, benzene derivatives, and aromatic aldehydes and ketones were used to evaluate the CEC performances of both nondeactivated and deactivated open tubular sol-gel columns. The effects of mobile-phase organic modifier contents and pH on EOF in such columns were evaluated. The prepared sol-gel ODS columns are characterized by switchable electroosmotic now. A pH value of similar to8.5 was found correspond to the isoelectric point for the prepared sol-gel ODS coatings.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 35 条
[11]   A STATIONARY-PHASE FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY AND ELECTROCHROMATOGRAPHY USING SOL-GEL TECHNOLOGY [J].
GUO, Y ;
COLON, LA .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2511-2516
[12]   Sol-gel chemistry-based Ucon-coated columns for capillary electrophoresis [J].
Hayes, JD ;
Malik, A .
JOURNAL OF CHROMATOGRAPHY B, 1997, 695 (01) :3-13
[13]   Sol-gel monolithic columns with reversed electroosmotic flow for capillary electrochromatography [J].
Hayes, JD ;
Malik, A .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4090-4099
[14]   STUDIES OF OPEN-TUBULAR MICROCAPILLARY LIQUID-CHROMATOGRAPHY .3. BETA,BETA'-OXYDIPROPIONITRILE AND ETHYLENE-GLYCOL STATIONARY PHASES [J].
HIBI, K ;
TSUDA, T ;
TAKEUCHI, T ;
NAKANISHI, T ;
ISHII, D .
JOURNAL OF CHROMATOGRAPHY, 1979, 175 (01) :105-111
[15]   STUDIES OF OPEN-TUBULAR MICROCAPILLARY LIQUID-CHROMATOGRAPHY .4. SODA-LIME GLASS-COLUMNS TREATED WITH ALKALINE-SOLUTION [J].
ISHII, D ;
TSUDA, T ;
TAKEUCHI, T .
JOURNAL OF CHROMATOGRAPHY, 1979, 185 (DEC) :73-78
[16]  
Jorgenson J W, 1984, J Pharm Biomed Anal, V2, P191, DOI 10.1016/0731-7085(84)80070-9
[17]   LIQUID-CHROMATOGRAPHY IN OPEN-TUBULAR COLUMNS - THEORY OF COLUMN OPTIMIZATION WITH LIMITED PRESSURE AND ANALYSIS TIME, AND FABRICATION OF CHEMICALLY BONDED REVERSED-PHASE COLUMNS ON ETCHED BOROSILICATE GLASS-CAPILLARIES [J].
JORGENSON, JW ;
GUTHRIE, EJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :335-348
[18]  
Malik A., 1999, APPL SOLID PHASE MIC, P73
[19]   Separation of tetracyclines by high-performance capillary electrophoresis and capillary electrochromatography [J].
Pesek, JJ ;
Matyska, MT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :313-320
[20]   Electrochromatography in chemically modified etched fused-silica capillaries [J].
Pesek, JJ ;
Matyska, MT .
JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) :255-264