Protein adsorption to organosiloxane surfaces studied by acoustic wave sensor

被引:20
作者
Cavic, BA [1 ]
Thompson, M [1 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
关键词
D O I
10.1039/a804225j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surfaces of the two organosiloxanes, polymercaptopropylmethylsiloxane and octaphenylcyclotetrasiloxane, were prepared on the gold electrodes of thickness-shear mode acoustic wave sensors,Compounds containing the siloxane bond are important in the fabrication of medical implants. The flow-through adsorption of the proteins: human serum albumin, alpha-chymotripsinogen A, cytochrome c, fibrinogen, hemoglobin, immunoglobulin G and apo-transferrin to the two siloxane surfaces and a gold electrode were detected by acoustic network analysis. With the exception of minor wash-off by buffer flow, the adsorption of all proteins to the three surfaces is irreversible. Differences observed for the magnitudes of adsorption for the various cases are ascribed to the role played by molecular interactions at the liquid/solid interface. The results confirm that changes in series resonant frequencies caused by macromolecular adsorption differ significantly from the widely accepted "mass based" model usually employed to characterize the response of this type of acoustic wave device.
引用
收藏
页码:2191 / 2196
页数:6
相关论文
共 55 条
  • [1] HIV SEROLOGY USING PIEZOELECTRIC IMMUNOSENSORS
    ABERL, F
    WOLF, H
    KOSSLINGER, C
    DROST, S
    WOIAS, P
    KOCH, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 18 (1-3) : 271 - 275
  • [2] ANDRADE JD, 1985, SURFACE INTERFACIAL, V2, P1
  • [3] FORMATION OF MONOLAYERS BY THE COADSORPTION OF THIOLS ON GOLD - VARIATION IN THE HEAD GROUP, TAIL GROUP, AND SOLVENT
    BAIN, CD
    EVALL, J
    WHITESIDES, GM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (18) : 7155 - 7164
  • [4] Baszkin A, 1995, ACS SYM SER, V602, P209
  • [5] Piezoelectric immunosensors for urine specimens of Chlamydia trachomatis employing quartz crystal microbalance microgravimetric analyses
    BenDov, I
    Willner, I
    Zisman, E
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3506 - 3512
  • [6] Brash J. L., 1995, ACS SYM SER, V602, P1
  • [7] Characterization of ferritin adsorption onto gold
    Caruso, F
    Furlong, DN
    Kingshott, P
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1997, 186 (01) : 129 - 140
  • [8] Cavic BA, 1997, FARADAY DISCUSS, V107, P159
  • [9] Silicones and their determination in biological matrices - A review
    CavicVlasak, BA
    Thompson, M
    Smith, DC
    [J]. ANALYST, 1996, 121 (06) : R53 - R63
  • [10] CONTINUOUS LIQUID-PHASE PIEZOELECTRIC BIOSENSOR FOR KINETIC IMMUNOASSAYS
    DAVIS, KA
    LEARY, TR
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (11) : 1227 - 1230