Effect of robotic milling on periprosthetic bone remodeling

被引:43
作者
Hananouchi, Takehito [1 ]
Sugano, Nobuhiko
Nishii, Takashi
Nakamura, Nobuo
Miki, Hidenobu
Kakimoto, Akihiro
Yamamura, Mitsuyoshi
Yoshikawa, Hideki
机构
[1] Osaka Univ, Grad Sch Med, Dept Orthoped, Osaka, Japan
[2] Kyowakai Hosp, Ctr Arthroplast, Osaka, Japan
关键词
ROBODOC system; periprosthetic bone remodeling;
D O I
10.1002/jor.20376
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The ROBODOC system has provided better fit and fill of the stem and less destruction of the bony architecture than with manual surgery. These benefits might affect femoral periprosthetic bone remodeling. We evaluated the effects of robotic milling in cementless total hip arthroplasty (THA) in a longitudinal 24-month follow-up study using dual energy X-ray absorptiometry (DEXA) and plain radiographs of 29 patients (31 hips) after ROBODOC THA and 24 patients (27 hips) after manual THA with the same stem design. To minimize the influence of other factors on bone remodeling, only female osteoarthritis patients, who had no drugs that might affect bone metabolism were enrolled. Significantly less bone loss occurred at the proximal periprosthetic areas in the ROBODOC group. In zone 1, the decrease was 15.5 versus 29.9% using conventional rasping; in zone 7, the loss was 17.0% with ROBODOC compared to 30.5% with conventional rasping (p < 0.05). On radiographs, endosteal spot welds in the proximal medial portion were more pronounced in the ROBODOC group (48 vs. 11% in the conventional group, p < 0.05). Our results suggest that robotic milling is effective in facilitating proximal load transfer around the femoral component and minimizing bone loss after cementless THA. (C) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:1062 / 1069
页数:8
相关论文
共 33 条
[1]
Pattern of periprosthetic bone remodeling around stable uncemented tapered hip stems: A prospective 84-month follow-up study and a median 156-month cross-sectional study with DXA [J].
Aldinger, PR ;
Sabo, D ;
Pritsch, M ;
Thomsen, M ;
Mau, H ;
Ewerbeck, V ;
Breusch, SJ .
CALCIFIED TISSUE INTERNATIONAL, 2003, 73 (02) :115-121
[2]
Bone strength influences periprosthetic bone loss after hip arthroplasty [J].
Arabmotlagh, M ;
Hennigs, T ;
Warzecha, J ;
Rittmeister, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :178-183
[3]
Alendronate prevents femoral periprosthetic bone loss following total hip arthroplasty: Prospective randomized double-blind study [J].
Arabmotlagh, Mohammad ;
Rittmeister, Markus ;
Hennigs, Thorsten .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (07) :1336-1341
[4]
Bargar WL, 1998, CLIN ORTHOP RELAT R, P82
[5]
BERMAN AT, 1984, CLIN ORTHOP RELAT R, P284
[6]
No adverse effects of early weight bearing after uncemented total hip arthroplasty -: A randomized study of 20 patients [J].
Bodén, H ;
Adolphson, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (01) :21-29
[7]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[8]
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[9]
POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[10]
6-YEAR RESULTS OF HYDROXYAPATITE-COATED TOTAL HIP-REPLACEMENT [J].
GEESINK, RGT ;
HOEFNAGELS, NHM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (04) :534-547