Real-time MR imaging of myocardial regional function using strain-encoding (SENC) with tissue through-plane motion tracking

被引:32
作者
Ibrahim, El-Sayed H. [1 ,2 ]
Stuber, Matthias [1 ,2 ,3 ]
Fahmy, Ahmed S. [1 ,2 ]
Abd-Elmoniem, Khaled Z. [1 ,2 ]
Sasano, Tetsuo [3 ]
Abraham, M. Roselle [3 ]
Osman, Nael F. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Med, Div Cardiol, Baltimore, MD USA
关键词
MRI; cardiac; SENC; strain; real-time imaging; slice-following;
D O I
10.1002/jmri.21125
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. Materials and Methods: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. Results: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC Images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. Conclusion: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.
引用
收藏
页码:1461 / 1470
页数:10
相关论文
共 24 条
[1]   DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI [J].
Aletras, AH ;
Ding, SJ ;
Balaban, RS ;
Wen, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :247-252
[2]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[3]   Correction of through-plane deformation artifacts in stimulated echo acquisition mode cardiac imaging [J].
Fahmy, AS ;
Pan, L ;
Stuber, M ;
Osman, NF .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :404-412
[4]  
FAHMY AS, 2005, J CARDIOVASC MAGN R, V7, P285
[5]   TRUE MYOCARDIAL MOTION TRACKING [J].
FISCHER, SE ;
MCKINNON, GC ;
SCHEIDEGGER, MB ;
PRINS, W ;
MEIER, D ;
BOESIGER, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :401-413
[6]   IMPROVED MYOCARDIAL TAGGING CONTRAST [J].
FISCHER, SE ;
MCKINNON, GC ;
MAIER, SE ;
BOESIGER, P .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :191-200
[7]   STIMULATED ECHO IMAGING [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :81-93
[8]   HIGH-SPEED STEAM MRI OF THE HUMAN HEART [J].
FRAHM, J ;
HANICKE, W ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) :133-142
[9]   Spatially resolved imaging of myocardial function with strain-encoded MR: Comparison with delayed contrast-enhanced MR imaging after myocardial infarction [J].
Garot, J ;
Lima, JAC ;
Gerber, BL ;
Sampath, S ;
Wu, KC ;
Bluemke, DA ;
Prince, JL ;
Osman, NF .
RADIOLOGY, 2004, 233 (02) :596-602
[10]   OFF-AXIS SPATIAL LOCALIZATION WITH FREQUENCY MODULATED NUCLEAR MAGNETIC-RESONANCE ROTATING (RHO) PULSES [J].
HARDY, CJ ;
BOTTOMLEY, PA ;
ROEMER, PB .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (09) :4741-4743