A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode

被引:273
作者
Lim, SH
Wei, J
Lin, JY [1 ]
Li, QT
KuaYou, J
机构
[1] Natl Univ Singapore, Dept Phys, Singapore 119260, Singapore
[2] Natl Univ Singapore, Dept Biochem, Singapore 119260, Singapore
[3] Xiamen Univ, Dept Chem, Xiamen 361005, Peoples R China
关键词
electrodeposition; palladium nanoparticles; Nafion;
D O I
10.1016/j.bios.2004.08.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrodeposition was used for the co-deposition of glucose oxidase (GOx) enzymes and palladium nanoparticles onto a Nation-solubilized carbon nanotube (CNT) film. The co-deposited Pd-GOx-Nafion CNT bioelectrode retains its biocatalytic activity and offers an efficient oxidation and reduction of the enzymatically liberated H2O2, allowing for fast and sensitive glucose quantification. The combination of Pd-GOx electrodeposition with Nafion-solubilized CNTs enhances the storage time and performance of the sensor. An extra Nafion coating was used to eliminate common interferents such as uric and ascorbic acids. The fabricated Pd-GOx-Nafion CNT glucose biosensor exhibits a linear response up to 12 mM glucose and a detection limit of 0.15 mM (S/N=3). (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:2341 / 2346
页数:6
相关论文
共 20 条
[1]   Bioelectrochemical single-walled carbon nanotubes [J].
Azamian, BR ;
Davis, JJ ;
Coleman, KS ;
Bagshaw, CB ;
Green, MLH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) :12664-12665
[2]  
CARDOSI MF, 1990, ADV BIOSENSORS
[3]   FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1993, 278 (01) :17-23
[4]   Protein electrochemistry at carbon nanotube electrodes [J].
Davis, JJ ;
Coles, RJ ;
Hill, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2) :279-282
[5]   Direct electron transfer of glucose oxidase on carbon nanotubes [J].
Guiseppi-Elie, A ;
Lei, CH ;
Baughman, RH .
NANOTECHNOLOGY, 2002, 13 (05) :559-564
[6]   ELECTROCHEMICAL FABRICATION OF AMPEROMETRIC MICROENZYME SENSOR [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
YUKIASHI, T ;
USHIODA, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (03) :702-706
[7]   Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode [J].
Liu, SQ ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :177-183
[8]   Non-aqueous enzymology approach for improvement of reagentless mediator-based glucose biosensor [J].
Lukachova, LV ;
Karyakin, AA ;
Ivanova, YN ;
Karyakina, EE ;
Varfolomeyev, SD .
ANALYST, 1998, 123 (10) :1981-1985
[9]  
Miscoria SA, 2002, ELECTROANAL, V14, P981, DOI 10.1002/1521-4109(200208)14:14<981::AID-ELAN981>3.0.CO
[10]  
2-1