Clinical relevance of imaging proliferative activity in lung nodules

被引:85
作者
Buck, AK
Hetzel, M
Schirrmeister, H
Halter, G
Möller, P
Kratochwil, C
Wahl, A
Glatting, G
Mottaghy, FM
Mattfeldt, T
Neumaier, B
Reske, SN
机构
[1] Univ Ulm, Dept Nucl Med, D-89081 Ulm, Germany
[2] Univ Ulm, Dept Internal Med 2, D-7900 Ulm, Germany
[3] Univ Ulm, Dept Thorac Surg, Ulm, Germany
[4] Univ Ulm, Dept Pathol, Ulm, Germany
关键词
PET; F-18]FLT; F-18]FDG; lung nodules; staging;
D O I
10.1007/s00259-004-1706-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Recently, the thymidine analogue 3'-deoxy- 3'[F-18] fluorothymidine (FLT) has been introduced for imaging proliferation with positron emission tomography ( PET). In this prospective study, we examined the accuracy of FLT for differentiation of benign from malignant lung lesions and for tumour staging. Methods: A total of 47 patients with newly diagnosed pulmonary nodules on chest CT suspicious for malignancy were examined with FLT-PET in addition to routine staging procedures. A total of 43 patients also underwent 2-[F-18] fluoro-2-deoxy-D-glucose (FDG) PET imaging. Within 2 weeks, patients underwent resective surgery or core biopsy of the pulmonary lesion. Results: Histopathology revealed malignant lung tumours in 32 patients ( 20 non-small cell lung cancer, 1 small cell lung cancer, 1 pulmonary carcinoid, 1 non-Hodgkin's lymphoma, nine metastases from extrapulmonary tumours) and benign lesions in 15 patients. Increased FLT uptake was exclusively related to malignant tumours. FLT-PET was false negative in two patients with non-small cell lung cancer, in the patient with a pulmonary carcinoid and in three patients with lung metastases. The sensitivity of FLT-PET for detection of lung cancer was 90%, the specificity 100% and the accuracy 94%. Fifteen out of 21 patients with lung cancer had mediastinal lymph node metastases. FLT-PET was true positive in 7/15 patients, resulting in a sensitivity of 53% for N-staging ( specificity 100%, accuracy 67%). Clinical TNM stage was correctly identified in 67% (20/30) patients, compared to 85% (23/27) with FDG-PET. Conclusion: FLT-PET has a high specificity for the detection of malignant lung tumours. Compared with FDG, FLT-PET is less accurate for N-staging in patients with lung cancer and for detection of lung metastases. FLT-PET therefore cannot be recommended for staging of lung cancer.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 36 条
[21]   [18F]FLT;: portrait of a proliferation marker [J].
Mier, W ;
Haberkorn, U ;
Eisenhut, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (02) :165-169
[22]  
Oyama N, 2004, J NUCL MED, V45, P519
[23]  
Rasey JS, 2002, J NUCL MED, V43, P1210
[24]  
SCHMIDLIN P, 1994, EUR J NUCL MED, V21, P930
[25]   Evaluation of pyrimidine metabolising enzymes and in vitro uptake of 3′-[18F]fluoro-3′-deoxythymidine ([18F]FLT) in pancreatic cancer cell lines [J].
Seitz, U ;
Wagner, M ;
Neumaier, B ;
Wawra, E ;
Glatting, G ;
Leder, G ;
Schmid, RM ;
Reske, SN .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (09) :1174-1181
[26]   Development of labeled thymidine analogs for imaging tumor proliferation [J].
Shields, AF ;
Grierson, JR ;
Kozawa, SM ;
Zheng, M .
NUCLEAR MEDICINE AND BIOLOGY, 1996, 23 (01) :17-22
[27]  
Shields AF, 2003, J NUCL MED, V44, P1432
[28]   Imaging proliferation in vivo with [F-18]FLT and positron emission tomography [J].
Shields, AF ;
Grierson, JR ;
Dohmen, BM ;
Machulla, HJ ;
Stayanoff, JC ;
Lawhorn-Crews, JM ;
Obradovich, JE ;
Muzik, O ;
Mangner, TJ .
NATURE MEDICINE, 1998, 4 (11) :1334-1336
[29]  
SHIELDS AF, 1984, J NUCL MED, V25, P759
[30]   Pitfalls in oncologic diagnosis with FDG PET imaging: Physiologic and benign variants [J].
Shreve, PD ;
Anzai, Y ;
Wahl, RL .
RADIOGRAPHICS, 1999, 19 (01) :61-77