Poly(dicarbazole-N-hydroxysuccinimide) film: a new polymer for the reagentless grafting of enzymes and redox mediators

被引:23
作者
Cosnier, S
Fologea, D
Szunerits, S
Marks, RS
机构
[1] Univ Grenoble 1, CNRS, UMR 5630, Lab Electrochim Organ & Photochim Redox, F-38041 Grenoble 9, France
[2] Ben Gurion Univ Negev, Inst Appl Biosci, IL-84105 Beer Sheva, Israel
关键词
carbazole; electropolymerisation; biosensor; polyphenol oxidase; thionine;
D O I
10.1016/S1388-2481(00)00131-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Upon oxidative electropolymerisation of a new dicarbazole derivative functionalised by a N-hydroxysuccinimide group in acetonitrile, electroactive poly(dicarbazole) films were formed on electrodes. The subsequent chemical functionalisation of the poly(dicarbazole) film was easily performed by successive immersions in aqueous enzyme and mediator solutions. Investigations by cyclic voltammetry showed that thionine and toluidine blue o have been irreversible bound to the poly(dicarbazole) backbone. The amperometric responses of the poly(dicarbazole) films grafted with polyphenol oxidase (PPO) and thionine to catechol were then investigated at -0.2 V vs. SCE. The catechol sensitivity and the maximum current at saturating catechol concentrations were 14.57 mA M-1 cm(-2) and 15.43 muA cm(-2), respectively. The comparison of this catechol sensitivity with that of a poly(dicarbazole) film only modified with PPO (3.40 mA M-1 cm(-2)) highlighted the improvement of the biosensor performance brought by thionine as immobilised redox mediator. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:827 / 831
页数:5
相关论文
共 50 条
[21]   ELECTROACTIVE POLY(3,6-CARBAZOLEDIYL) WITH LATERAL AMINOALKYLDISILOXANE GROUPS [J].
HELARY, G ;
CHEVROT, C ;
SAUVET, G ;
SIOVE, A .
POLYMER BULLETIN, 1991, 26 (02) :131-138
[22]   Potentiometric enzyme electrode for urea based on electrochemically prepared polypyrrole membranes [J].
Hernandez, EC ;
Witkowski, A ;
Daunert, S ;
Bachas, LG .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :63-72
[23]   Amperometric biosensors produced by immobilization of redox enzymes at polythiophene-modified electrode surfaces [J].
Hiller, M ;
Kranz, C ;
Huber, J ;
Bauerle, P ;
Schuhmann, W .
ADVANCED MATERIALS, 1996, 8 (03) :219-&
[24]  
Hiratsuka A, 2000, ELECTROANAL, V12, P695, DOI 10.1002/1521-4109(200005)12:9<695::AID-ELAN695>3.0.CO
[25]  
2-4
[26]  
KAUFFMANN JM, 1992, BIOANALYTICAL APPL E, V3
[27]   Toward bioelectronics: Specific DNA recognition based on an oligonucleotide-functionalized polypyrrole [J].
KorriYoussoufi, H ;
Garnier, F ;
Srivastava, P ;
Godillot, P ;
Yassar, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (31) :7388-7389
[28]  
Kranz C, 1998, ELECTROANAL, V10, P546, DOI 10.1002/(SICI)1521-4109(199807)10:8<546::AID-ELAN546>3.0.CO
[29]  
2-#
[30]   Microfabricated biosensors and microanalytical systems for blood analysis [J].
Lauks, IR .
ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) :317-324