Blood flow quantification with contrast-enhanced US: "Entrance in the section" phenomenon-phantom and rabbit study

被引:68
作者
Lucidarme, O
Franchi-Abella, S
Correas, JM
Bridal, SL
Kurtisovski, E
Berger, G
机构
[1] CNRS, UMR 7623, Parametr Imaging Lab, F-75006 Paris, France
[2] Univ Paris 06, F-75006 Paris, France
[3] Hop Necker Enfants Malad, AP HP, Dept Radiol, Paris, France
[4] Hop La Pitie Salpetriere, AP HP, Dept Radiol, Paris, France
关键词
blood; flow dynamics; kidney; US; microbubbles; phantoms; test objects; ultrasound; (US); contrast media;
D O I
10.1148/radiol.2282020699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate changes in destruction-replenishment curves (in vitro and in vivo) that result from microbubble destruction in feeding vessels that pass through the imaging plane before microbubbles enter the region of interest (ROI). MATERIALS AND METHODS: During continuous injections of an ultrasonographic contrast agent, nonlinear gray-scale images were obtained in vitro in the longitudinal plane of a renal dialysis cartridge flow phantom (flow rates of 100, 200, and 400 mL/min) and in vivo in the coronal plane of the left kidneys of two rabbits (two kidneys). Destruction-replenishment curves were obtained for the dialysis cartridge in ROIs located immediately after the entrance of the microbubbles into the image plane and further from the entrance, after microbubbles had traveled across the complete length of the imaging plane. Replenishment curves were also obtained from ROIs in the rabbit kidneys at the level of segmental arteries, distal interlobar arteries, and the cortex. RESULTS: The ROIs immediately after the entrance of the microbubbles in the image plane of the dialysis cartridge and in the segmental artery of the kidney followed a typical exponential function, A(1 - e(-alphat)). Early portions of curves obtained in ROIs filled with microbubbles that had already passed through the image plane of the dialysis cartridge or in the renal cortex were not well described by such a function. The shape of the curve and the variations as a function of flow rate can be explained by means of a mathematical model based on indicator-dilution theory. CONCLUSION: When the feeding vessels of an ROI travel across the ultrasound field before they reach the measurement region the typical shape of the replenishment curve is modified (reduced velocity parameter and plateau). (C) RSNA, 2003.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 13 条
[1]   Infusion versus bolus of an ultrasound contrast agent - In vivo dose-response measurements of BR1 [J].
Correas, JM ;
Burns, PN ;
Lai, XM ;
Qi, XL .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :72-79
[2]   Quantification of blood flow [J].
Cosgrove, D ;
Eckersley, R ;
Blomley, M ;
Harvey, C .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1338-1344
[3]   Assessment of transmural distribution of myocardial perfusion with contrast echocardiography [J].
Linka, AZ ;
Sklenar, J ;
Wei, K ;
Jayaweera, AR ;
Skyba, DM ;
Kaul, S .
CIRCULATION, 1998, 98 (18) :1912-1920
[4]   Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound [J].
Rim, SJ ;
Leong-Poi, H ;
Lindner, JR ;
Couture, D ;
Ellegala, D ;
Mason, H ;
Durieux, M ;
Kassel, NF ;
Kaul, S .
CIRCULATION, 2001, 104 (21) :2582-2587
[5]   Feasibility of the flash-replenishment concept in renal tissue:: Which parameters affect the assessment of the contrast replenishment? [J].
Schlosser, T ;
Pohl, C ;
Veltmann, C ;
Lohmaier, S ;
Goenechea, J ;
Ehlgen, A ;
Köster, J ;
Bimmel, D ;
Kuntz-Hehner, S ;
Becher, H ;
Tiemann, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07) :937-944
[6]   BR1 - A NEW ULTRASONOGRAPHIC CONTRAST AGENT BASED ON SULFUR HEXAFLUORIDE-FILLED MICROBUBBLES [J].
SCHNEIDER, M ;
ARDITI, M ;
BARRAU, MB ;
BROCHOT, J ;
BROILLET, A ;
VENTRONE, R ;
YAN, F .
INVESTIGATIVE RADIOLOGY, 1995, 30 (08) :451-457
[7]   WHEN CAN DOPPLER BE USED IN-PLACE OF INTEGRATED BACKSCATTER AS A MEASURE OF SCATTERED ULTRASOUND INTENSITY [J].
SCHWARZ, KQ ;
BEZANTE, GP ;
CHEN, XC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :231-242
[8]  
Seidel G, 2001, Eur J Ultrasound, V14, P103, DOI 10.1016/S0929-8266(01)00151-3
[9]   Evaluation of blood flow in the cerebral microcirculation: Analysis of the refill kinetics during ultrasound contrast agent infusion [J].
Seidel, G ;
Claassen, L ;
Meyer, K ;
Vidal-Langwasser, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (08) :1059-1064
[10]   Effect of acquisition rate on liver and portal vein enhancement with microbubble contrast [J].
Sirlin, CB ;
Girard, MS ;
Baker, KG ;
Steinbach, GC ;
Deiranieh, LH ;
Mattrey, RF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (03) :331-338