Advances in atomic fountains

被引:67
作者
Bize, S
Laurent, P
Abgrall, M
Marion, H
Maksimovic, I
Cacciapuoti, L
Grünert, J
Vian, C
dos Santos, FP
Rosenbusch, P
Lemonde, P
Santarelli, G
Wolf, P
Clairon, A
Luiten, A
Tobar, M
Salomon, C
机构
[1] Observ Paris, BNM, SYRTE, F-75014 Paris, France
[2] Univ Western Australia, Sch Phys, Crawley, WA, Australia
[3] ENS, Lab Kastler Brossel, F-75005 Paris, France
关键词
atomic fountains; microwave frequency standards; laser-cooled atoms; atomic clocks; PHARAO;
D O I
10.1016/j.crhy.2004.09.003
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
This article describes the work performed at BNM-SYRTE (Observatoire de Paris) in the past few years, toward the improvement and the use of microwave frequency standards using laser-cooled atoms. First, recent improvements of the Cs-133 and Rb-87 atomic fountains are described. An important advance is the achievement of a fractional frequency instability of 1.6 x 10(-14)tau(-1/2) where tau is the measurement time in seconds, thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a fractional frequency in stability of 2 x 10(-16) at 50000 s between two independent primary standards. In addition, these clocks realize the SI second with an accuracy of 7 x 10(-16), one order of magnitude below that of uncooled devices. Tests of fundamental physical laws constitute an important field of application for highly accurate atomic clocks. In a second part, we describe tests of possible variations of fundamental constants using Rb-87 and Cs-133 fountains. The third part is an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which will fly on board the International Space Station in 2007-2008, enabling a new generation of relativity tests. (c) 2004 Academie des sciences. Published by Elsevier SAS. All rights reserved.
引用
收藏
页码:829 / 843
页数:15
相关论文
共 65 条
[41]  
NARBONNEAU F, 2004, P 2004 EPTF C
[42]   Measurement of the hydrogen 1S-2S transition frequency by phase coherent comparison with a microwave cesium fountain clock [J].
Niering, M ;
Holzwarth, R ;
Reichert, J ;
Pokasov, P ;
Udem, T ;
Weitz, M ;
Hänsch, TW ;
Lemonde, P ;
Santarelli, G ;
Abgrall, M ;
Laurent, P ;
Salomon, C ;
Clairon, A .
PHYSICAL REVIEW LETTERS, 2000, 84 (24) :5496-5499
[43]   Efficient magneto-optical trapping of Yb atoms with a violet laser diode [J].
Park, CY ;
Yoon, TH .
PHYSICAL REVIEW A, 2003, 68 (05) :4
[44]   First comparison of remote cesium fountains [J].
Parker, T ;
Hetzel, P ;
Jefferts, S ;
Weyers, S ;
Nelson, L ;
Bauch, A ;
Levine, J .
PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, :63-68
[45]  
PEIK E, 2004, PHYSICS0402132
[46]  
PEIK E, 2003, P JOINT M IEEE INT F
[47]   Possibility of an optical clock using the 61S0→63P0o transition in 171,173Yb atoms held in an optical lattice -: art. no. 021403 [J].
Porsev, SG ;
Derevianko, A ;
Fortson, EN .
PHYSICAL REVIEW A, 2004, 69 (02) :4
[48]   ATOMIC CLOCKS AND VARIATIONS OF THE FINE-STRUCTURE CONSTANT [J].
PRESTAGE, JD ;
TJOELKER, RL ;
MALEKI, L .
PHYSICAL REVIEW LETTERS, 1995, 74 (18) :3511-3514
[49]  
RICHARD JY, 2004, P 2004 EFTF
[50]   Cold atoms in space and atomic clocks: ACES [J].
Salomon, C ;
Dimarcq, N ;
Abgrall, M ;
Clairon, A ;
Laurent, P ;
LeMonde, P ;
Santarelli, G ;
Uhrich, P ;
Bernier, LG ;
Busca, G ;
Jornod, A ;
Thomann, P ;
Samain, E ;
Wolf, P ;
Gonzalez, F ;
Guillemot, P ;
Leon, S ;
Nouel, F ;
Sirmain, C ;
Feltham, S .
COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE, 2001, 2 (09) :1313-1330