Permporometry characterization of microporous ceramic membranes

被引:139
作者
Tsuru, T [1 ]
Hino, T [1 ]
Yoshioka, T [1 ]
Asaeda, M [1 ]
机构
[1] Hiroshima Univ, Dept Chem Engn, Higashihiroshima 7398527, Japan
关键词
pore size; permporometry; ceramic membranes; microporous and porous membranes;
D O I
10.1016/S0376-7388(00)00692-X
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An evaluation of nano-order pore size of membranes was carried out using permporometry, the basic principle of which is based on capillary condensation of vapor and the blocking effect of permeation of a non-condensable gas. A computer-controlled apparatus was constructed, where liquid was injected by a syringe pump and nitrogen was used as a carrier, and was applied to the evaluation of the pore size of ceramic membranes prepared from a silica-zirconia composite. The pore size distribution, based on the Kelvin equation (Kelvin diameter), was evaluated over a range of 0.5-30 nm, using water as a condensable vapor. Vapors used in the present study were water, methanol, ethanol, isopropanol, carbon tetrachloride, and hexane. For the case of relatively large pore sizes (larger than 1 nm, based on water vapor), pore size distribution obtained by water vapor agreed very well with those by carbon tetrachloride and hexane. However, pore sizes measured using alcohols were found to be smaller than those determined by water vapor. For the case of pore sizes smaller than 1 nm, the adsorption layer before capillary condensation appears to play an important role. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 15 条
[1]  
ASAEDA M, 1991, KEY ENG MATER, V61, P295
[2]  
ASAEDA M, 1996, P 4 INT C IN MEMBR G, P68
[3]   Permeation of ethanol and methanol vapours through a porous alumina membrane [J].
Assabumrungrat, S ;
White, DA .
CHEMICAL ENGINEERING SCIENCE, 1996, 51 (24) :5241-5250
[4]  
Breck D.W, 1974, ZEOLITE MOL SIEVES
[5]   PERMPOROMETRY STUDY ON THE SIZE DISTRIBUTION OF ACTIVE PORES IN POROUS CERAMIC MEMBRANES [J].
CAO, GZ ;
MEIJERINK, J ;
BRINKMAN, HW ;
BURGGRAAF, AJ .
JOURNAL OF MEMBRANE SCIENCE, 1993, 83 (02) :221-235
[6]   CHARACTERIZATION OF ANISOTROPIC UF-MEMBRANES - TOP LAYER THICKNESS AND PORE STRUCTURE [J].
CUPERUS, FP ;
BARGEMAN, D ;
SMOLDERS, CA .
JOURNAL OF MEMBRANE SCIENCE, 1991, 61 :73-83
[7]   PERMPOROMETRY - THE DETERMINATION OF THE SIZE DISTRIBUTION OF ACTIVE PORES IN UF MEMBRANES [J].
CUPERUS, FP ;
BARGEMAN, D ;
SMOLDERS, CA .
JOURNAL OF MEMBRANE SCIENCE, 1992, 71 (1-2) :57-67
[8]  
FAIN DE, 1989, P 1 INT C IN MEMBR M, P199
[9]   Characterization of asymmetric ceramic membranes by modified permporometry [J].
Huang, P ;
Xu, NP ;
Shi, J ;
Lin, YS .
JOURNAL OF MEMBRANE SCIENCE, 1996, 116 (02) :301-305
[10]   NEW INSIGHTS INTO THE STRUCTURE OF MICROPOROUS MEMBRANES OBTAINED USING A NEW PORE-SIZE EVALUATION METHOD [J].
KATZ, MG ;
BARUCH, G .
DESALINATION, 1986, 58 (03) :199-211