We have designed and fabricated a polydimethylsiloxane (PDMS) microfluidic device containing an array of gold spots onto which antigens or antibodies of interest can be attached. We use surface plasmon resonance (SPR) imaging to monitor the antibody-antigen recognition and binding events. This combination offers two significant advantages: (1) the microfluidic device dramatically reduces reaction time and sample consumption; and (2) the SPR imaging yields real-time detection of the immunocomplex formation. Thus, an immunoreaction may be detected and quantitatively characterized in about 10 min. The sensitivity of this method is at the subnanomolar level. When gold nanoparticles are selectively coupled to the immunocomplex to cause signal amplification, the sensitivity reaches the ten to one hundred picomolar level but the time required increases to about 60 min.
引用
收藏
页码:694 / 700
页数:7
相关论文
共 28 条
[11]   Design of a compact disk-like microfluidic platform for enzyme-linked immunosorbent assay [J].
Lai, S ;
Wang, SN ;
Luo, J ;
Lee, LJ ;
Yang, ST ;
Madou, MJ .
ANALYTICAL CHEMISTRY, 2004, 76 (07) :1832-1837
[12]   Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay [J].
Lee, Kuo-Hoong ;
Su, Yuan-Deng ;
Chen, Shean-Jen ;
Tseng, Fan-Gang ;
Lee, Gwo-Bin .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (04) :466-472
[13]   Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA) [J].
Lequin, RM .
CLINICAL CHEMISTRY, 2005, 51 (12) :2415-2418
[14]   Development of a novel microfluidic immunoassay for the detection of Helicobacter pylori infection [J].
Lin, FYH ;
Sabri, M ;
Erickson, D ;
Alirezaie, J ;
Li, DQ ;
Sherman, PM .
ANALYST, 2004, 129 (09) :823-828
[15]   Protein contact printing for a surface plasmon resonance biosensor with on-chip referencing [J].
Lu, HB ;
Homola, J ;
Campbell, CT ;
Nenninger, GG ;
Yee, SS ;
Ratner, BD .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :91-99
[16]  
PROBSTEIN RF, 2003, PHYSIOCHEMICAL HYDRO
[17]   Enzyme linked immunosorbent assay on a microchip with electrochemical detection [J].
Rossier, JS ;
Girault, HH .
LAB ON A CHIP, 2001, 1 (02) :153-157
[18]   SURFACE-PLASMON MICROSCOPY [J].
ROTHENHAUSLER, B ;
KNOLL, W .
NATURE, 1988, 332 (6165) :615-617
[19]  
Sato K, 2002, ELECTROPHORESIS, V23, P734, DOI 10.1002/1522-2683(200203)23:5<734::AID-ELPS734>3.0.CO
[20]  
2-W