A randomized, prospective, comparative study of manual and automated renal biopsies

被引:78
作者
Kim, D
Kim, H
Shin, G
Ku, S
Ma, KG
Shin, S
Gi, H
Lee, E
Yim, H
机构
[1] Ajou Univ, Sch Med, Dept Nephrol, Suwon 442749, South Korea
[2] Ajou Univ, Sch Med, Dept Radiol, Suwon 442749, South Korea
[3] Ajou Univ, Sch Med, Dept Pathol, Suwon 442749, South Korea
关键词
percutaneous renal biopsy; biopsy gun; Tru-cut needle; complication; perirenal hematoma;
D O I
10.1053/ajkd.1998.v32.pm9740159
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
A percutaneous renal biopsy can be performed in several ways, including using a spring-loaded biopsy gun. As this form of renal biopsy has become more popular, a controversy has developed regarding tissue adequacy and the incidence of complications. To compare these two aspects in an automated biopsy and a manual biopsy, we studied 166 patients assigned to one of the two renal biopsy methods. In a randomized, prospective manner from June 1994 until February 1997, group 1 (67 patients) received a 14 G Tru-cut needle (Baxter, Deerfield, IL) manual biopsy while group 2 (99 patients) received an 18 G automated gun biopsy. There was no difference in sex, age, hemoglobin level, prothrombin time, partial thromboplastin time, or diastolic and systolic blood pressure prebiopsy in groups I and II. Indications for biopsy were proteinuria (38%), proteinuria accompanied by hematuria (31.3%), acute renal failure (9.6%), lupus nephropathy (9.6%), chronic renal failure (6%), and hematuria only (5.4%). In group I, the number of cores was 1.88 +/- 0.56, the glomeruli obtained were 27.3 +/- 13.8, and the number of glomeruli per core were 15.3 +/- 8.4. In group II, the values were 2.37 +/- 0.88, 20.7 +/- 11.1,and 9.95 +/- 6.9, respectively. These results showed a statistically significant difference (P < 0.05). In all cases, pathological diagnosis was possible. The histology showed IgA nephropathy in 25.9%, minimal change disease in 16.3%, lupus nephritis in 11.4%, membranous glomerulonephropathy in 9.3%, membranoproliferative glomerulonephritis in 5.4%, and others. The incidence of postbiopsy hematoma was marginally greater in group I (22.3% v 11.1%) and the area of perirenal hematoma shown on ultrasound 24 hours postbiopsy was larger in group I, as well (848 +/- 623 mm(2) v 338 +/- 260 mm(2)). Hematocrit levels before and after biopsy showed a significant difference (34.9% +/- 7.9% and 34.0% +/- 7.6%, respectively; P < 0.05) In group I, but no significant difference was observed in group II (35.1% +/- 7.0% and 34.7% +/- 6.9%). Both techniques rendered adequate tissue sampling, but the extent of bleeding was more severe with the manual 14 G Tru-cut needle biopsy. (C) 1998 by the National Kidney Foundation, Inc.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 31 条
[31]   PERCUTANEOUS RENAL BIOPSY UTILIZING REAL-TIME, ULTRASONIC GUIDANCE AND A SEMIAUTOMATED BIOPSY DEVICE [J].
WISEMAN, DA ;
HAWKINS, R ;
NUMEROW, LM ;
TAUB, KJ .
KIDNEY INTERNATIONAL, 1990, 38 (02) :347-349