Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements

被引:248
作者
Günther, M [1 ]
Oshio, K [1 ]
Feinberg, DA [1 ]
机构
[1] Adv MRI Technol, Sebastopol, CA 95472 USA
关键词
perfusion; arterial spin labeling; GRASE; single-shot; 3D; imaging technique; high signal-to-noise ratio;
D O I
10.1002/mrm.20580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial spin labeling (ASL) can be used to measure perfusion without the use of contrast agents. Due to the small volume fraction of blood vessels compared to tissue in the human brain (typ. 3-5%) ASL techniques have an intrinsically low signal-to-noise ratio (SNR). In this publication, evidence is presented that the SNR can be improved by using arterial spin labeling in combination with single-shot 3D readout techniques. Specifically, a single-shot 3D-GRASE sequence is presented, which yields a 2.8-fold increase in SNR compared to 2D EPI at the same nominal resolution. Up to 18 slices can be acquired in 2 min with an SNR of 10 or more for gray matter perfusion. A method is proposed to increase the reliability of perfusion quantification using QUIPSS II derivates by acquiring low-resolution maps of the bolus arrival time, which allows differentiation between lack of perfusion and delayed arrival of the labeled blood. For arterial spin labeling, single-shot 3D imaging techniques are optimal in terms of efficiency and might prove beneficial to improve reliability of perfusion quantitation in a clinical setup.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 16 条
[1]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[2]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[3]  
GUNTHER M, 2000, P 8 ANN M ISMRM DENV, P168
[4]   Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: Principles and applications to hyperecho and TRAPS sequences [J].
Hennig, J ;
Weigel, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :68-80
[5]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[6]  
Luh WM, 1999, MAGNET RESON MED, V41, P1246, DOI 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO
[7]  
2-N
[8]   Background suppression with multiple inversion recovery nulling: Applications to projective angiography [J].
Mani, S ;
Pauly, J ;
Conolly, S ;
Meyer, C ;
Nishimura, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :898-905
[9]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[10]   ECHO-VOLUME IMAGING [J].
SONG, AW ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :668-671