Background suppression with multiple inversion recovery nulling: Applications to projective angiography

被引:60
作者
Mani, S
Pauly, J
Conolly, S
Meyer, C
Nishimura, D
机构
[1] STANFORD UNIV, MAGNET RESONANCE SYST RES LAB, DEPT APPL PHYS, STANFORD, CA 94305 USA
[2] STANFORD UNIV, DEPT ELECT ENGN, STANFORD, CA 94305 USA
关键词
multiple inversion recovery; magnetic resonance angiography; suppression;
D O I
10.1002/mrm.1910370615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a technique to accurately null the longitudinal magnetization (M-z) of background material. This suppression involves first saturating the longitudinal magnetization (M-z) of a region, and then applying several nonselective inversions. The inversions are timed relative to the saturation such that M-z is nulled across a broad range of T-1 at a predetermined time after the initial saturation, B-1 and B-0 inhomogeneity, which could lead to inaccurate suppression, are dealt with by the combination of a multiple tip saturation sequence and four adiabatic inversion pulses. The suppression sequence can be used to form projective angiograms by selectively tagging the imaging region with the saturation pulse. After the inversions are played out, a projection taken through the tag region when M-z is nulled will only contain signal from blood that has flown into the region after the saturation. Since only two dimensions are acquired, the technique can acquire gated projection angiograms in reasonable scan times. Representative inflow MIR angiograms of the carotid arteries and renal arteries show excellent background suppression.
引用
收藏
页码:898 / 905
页数:8
相关论文
共 21 条
[1]   MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS [J].
ANDERSON, CM ;
LEE, RE ;
LEVIN, DL ;
ALONSO, SD ;
SALONER, D .
RADIOLOGY, 1994, 193 (01) :219-226
[2]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[3]   RENAL-ARTERIES - CLINICAL COMPARISON OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHIC SEQUENCES AND RADIOGRAPHIC ANGIOGRAPHY [J].
BORRELLO, JA ;
LI, DB ;
VESELY, TM ;
VINING, EP ;
BROWN, JJ ;
HAACKE, EM .
RADIOLOGY, 1995, 197 (03) :793-799
[4]   SWEEP-DIAGRAM ANALYSIS OF SELECTIVE ADIABATIC PULSES [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (03) :549-564
[5]   MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS [J].
DIXON, WT ;
SARDASHTI, M ;
CASTILLO, M ;
STOMP, GP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :257-268
[6]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[7]  
Ganong WilliamF., 2005, REV MED PHYSL
[8]   H-1-NMR CHEMICAL-SHIFT SELECTIVE (CHESS) IMAGING [J].
HAASE, A ;
FRAHM, J ;
HANICKE, W ;
MATTHAEI, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (04) :341-344
[9]  
KERR AB, P SMR 1 ANN M DALL 1, pP205
[10]   3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY USING SELECTIVE INVERSION-RECOVERY RAGE WITH FAT-SATURATION AND ECG-TRIGGERING - APPLICATION TO RENAL-ARTERIES [J].
LI, D ;
HAACKE, EM ;
MUGLER, JP ;
BERR, S ;
BROOKEMAN, JR ;
HUTTON, MC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :414-422