RENAL-ARTERIES - CLINICAL COMPARISON OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHIC SEQUENCES AND RADIOGRAPHIC ANGIOGRAPHY

被引:27
作者
BORRELLO, JA
LI, DB
VESELY, TM
VINING, EP
BROWN, JJ
HAACKE, EM
机构
[1] Mallinckrodt Institute of Radiology, Washington University, School of Medicine, St. Louis, MO 63110
关键词
MAGNETIC RESONANCE (MR); VASCULAR STUDIES; RENAL ARTERIES; MR; STENOSIS OR OBSTRUCTION;
D O I
10.1148/radiology.197.3.7480758
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare three magnetic resonance (MR) angiographic t MATERIALS AND METHODS: Twenty-five adult patients underwent three-dimensional time-of-flight MR angiography with three different sequences: conventional, tilted optimized nonsaturating excitation (TONE), and selective inversion-recovery rapid gradient-echo (SIR-RAGE). Fifteen also underwent radiographic angiography, Stenosis grade measured with each MR angiographic technique was compared with that measured with radiographic angiography by using correlation coefficients. Visible artery lengths with each MR angiographic technique were compared by using the Tukey method. RESULTS: Correlation between stenosis grades with each MR angiographic technique and with radiographic angiography was good (P < .01). Stenosis was correctly excluded with SIR-RAGE findings in six patients. Mean visible artery length was greatest with SIR-RAGE (P < .01). CONCLUSION: SIR-RAGE depicts a greater length of renal artery than does conventional MR angiography. TONE also improved depiction of distal arteries. Normal SIR-RAGE findings were highly predictive of normal arteries.
引用
收藏
页码:793 / 799
页数:7
相关论文
共 28 条
  • [1] MEASUREMENT OF INTERNAL CAROTID-ARTERY STENOSIS FROM SOURCE MR ANGIOGRAMS
    ANDERSON, CM
    LEE, RE
    LEVIN, DL
    ALONSO, SD
    SALONER, D
    [J]. RADIOLOGY, 1994, 193 (01) : 219 - 226
  • [2] EVALUATION OF 2D- AND 3D-TIME-OF-FLIGHT-MRA IN RENAL-ARTERY STENOSIS
    ARLART, IP
    GUHL, L
    HAUSMANN, R
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (01): : 59 - 64
  • [3] CRITICAL ARTERIAL-STENOSIS - THEORETICAL AND EXPERIMENTAL SOLUTION
    BERGUER, R
    HWANG, NHC
    [J]. ANNALS OF SURGERY, 1974, 180 (01) : 39 - 50
  • [4] RENAL MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PREOPERATIVE DETECTION OF SUPERNUMERARY RENAL-ARTERIES IN POTENTIAL KIDNEY DONORS
    DEBATIN, JF
    SOSTMAN, HD
    KNELSON, M
    ARGABRIGHT, M
    SPRITZER, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (10) : 882 - 889
  • [5] IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY
    DEBATIN, JF
    SPRITZER, CE
    GRIST, TM
    BEAM, C
    SVETKEY, LP
    NEWMAN, GE
    SOSTMAN, HD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) : 981 - 990
  • [6] DUDA SH, RADIOLOGY P, V193, P302
  • [7] GEDROYC WMW, 1994, UROL CLIN N AM, V21, P201
  • [8] GRIST TM, 1993, 12TH P SMRM ANN SCI, P187
  • [9] OPTIMIZING BLOOD-VESSEL CONTRAST IN FAST 3-DIMENSIONAL MRI
    HAACKE, EM
    MASARYK, TJ
    WIELOPOLSKI, PA
    ZYPMAN, FR
    TKACH, JA
    AMARTUR, S
    MITCHELL, J
    CLAMPITT, M
    PASCHAL, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 202 - 221
  • [10] EVALUATION OF RENAL-ARTERY STENOSIS BY MAGNETIC-RESONANCE ANGIOGRAPHY
    HERTZ, SM
    HOLLAND, GA
    BAUM, RA
    HASKAL, ZJ
    CARPENTER, JP
    [J]. AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) : 140 - 143