Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection

被引:190
作者
Fu, I [1 ]
Woolf, EJ [1 ]
Matuszewski, BK [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, W Point, PA 19486 USA
关键词
indinavir; matrix effect; liquid chromatography-tandem mass spectrometry; turbo ion spray;
D O I
10.1016/S0731-7085(98)00048-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The HPLC/tandem mass spectrometric (LC/MS/MS) behavior of indinavir, an HIV protease inhibitor, in human urine is presented as an example of a case where endogenous matrix components were found to interfere with the ionization of the target analyte. The MS/MS system used for these experiments was equipped with a turbo ion spray LC interface. Results from two sample preparation procedures (direct dilution of urine vs urine extraction) and two chromatographic systems (low vs. high capacity factor (k')) for the analytes were compared. Additionally, the precision of the analysis that was achieved while using a stable isotope labeled internal standard is contrasted with the results obtained using an analog of indinavir as internal standard. The results obtained indicated that during development and validation of LC/MS/MS based assays the potential effect of co-eluting 'unseen' endogenous species should be evaluated to ensure that sample preparation and chromatography is adequate to overcome the matrix effect problems. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:347 / 357
页数:11
相关论文
共 20 条
[1]  
Balani SK, 1996, DRUG METAB DISPOS, V24, P1389
[2]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[3]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[4]   DETERMINATION OF PIRENZEPINE IN HUMAN PLASMA USING LIQUID-CHROMATOGRAPHY WITH TANDEM MASS-SPECTROMETRIC DETECTION [J].
CHAVEZ, CM ;
CONSTANZER, ML ;
MATUSZEWSKI, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (09) :1179-1184
[5]   DEVELOPMENT AND COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS WITH TANDEM MASS-SPECTROMETRIC AND ULTRAVIOLET ABSORBENCY DETECTION FOR THE DETERMINATION OF CYCLOBENZAPRINE IN HUMAN PLASMA AND URINE [J].
CONSTANZER, M ;
CHAVEZ, C ;
MATUSZEWSKI, B .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01) :117-126
[6]   Low level determination of a novel 4-azasteroid and its carboxylic acid metabolite in human plasma and semen using high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry [J].
Constanzer, ML ;
Chavez, CM ;
Matuszewski, BK ;
Carlin, J ;
Graham, D .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01) :117-129
[7]   Determination of a novel growth hormone secretagogue (MK-677) in human plasma at picogram levels by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry [J].
Constanzer, ML ;
ChavezEng, CM ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01) :131-137
[8]   PICOGRAM DETERMINATION OF FINASTERIDE IN HUMAN PLASMA AND SEMEN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ATMOSPHERIC-PRESSURE CHEMICAL-IONIZATION TANDEM MASS-SPECTROMETRY [J].
CONSTANZER, ML ;
CHAVEZ, CM ;
MATUSZEWSKI, BK .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02) :281-287
[9]   Low level determination of dorzolamide and its de-ethylated metabolite in human plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry [J].
Constanzer, ML ;
Chavez, CM ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (07) :1001-1008
[10]   HIGH-SPEED LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY FOR THE DETERMINATION OF DRUGS IN BIOLOGICAL SAMPLES [J].
COVEY, TR ;
LEE, ED ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2453-2460