Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array

被引:153
作者
Choi, S [1 ]
Park, JK [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Biosyst, Taejon 305701, South Korea
关键词
D O I
10.1039/b505088j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane) (PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA in the microfluidic channel and are dielectrophoretically focused to make all of them line up to one sidewall. When these particles arrive at the region of another TEA for dielectrophoretic separation, they are separated having different positions along the perpendicular direction to the fluid flow due to their different dielectrophoretic velocities. To evaluate the separation process and performance, both the effect of the flow rate on dielectrophoretic focusing and the influence of the number of trapezoidal electrodes on dielectrophoretic separation are investigated. Now that this method utilizes the TEA as a source of negative DEP, non-specific particle adhering to the electrode surface can be prevented; conventional separation approaches depending on the positive DEP force suffer from this problem. In addition, since various particle types are continuously separated, this method can be easily applicable to the separation and analysis of various dielectric particles with high particle recovery and selectivity.
引用
收藏
页码:1161 / 1167
页数:7
相关论文
共 34 条
  • [31] Differential analysis of human leukocytes by dielectrophoretic field-flow-fractionation
    Yang, J
    Huang, Y
    Wang, XB
    Becker, FF
    Gascoyne, PRC
    [J]. BIOPHYSICAL JOURNAL, 2000, 78 (05) : 2680 - 2689
  • [32] Dielectric properties of human leukocyte subpopulations determined by electrorotation as a cell separation criterion
    Yang, J
    Huang, Y
    Wang, XJ
    Wang, XB
    Becker, FF
    Gascoyne, PRC
    [J]. BIOPHYSICAL JOURNAL, 1999, 76 (06) : 3307 - 3314
  • [33] Negative dielectrophoretic force assisted construction of ordered neuronal networks on cell positioning bioelectronic chips
    Yu, Z
    Xiang, GX
    Pan, LB
    Huang, LH
    Yu, ZY
    Xing, WL
    Cheng, J
    [J]. BIOMEDICAL MICRODEVICES, 2004, 6 (04) : 311 - 324
  • [34] A simple and rapid method for removal of specific cell populations from whole blood
    Zwerner, RK
    Schmittling, RJ
    Russell, TR
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1996, 198 (02) : 199 - 202