Intracranial aneurysms: Detection with three-dimensional CT angiography with volume rendering - Comparison with conventional angiographic and surgical findings

被引:142
作者
Korogi, Y
Takahashi, M
Katada, K
Ogura, Y
Hasuo, K
Ochi, M
Utsunomiya, H
Abe, T
Imakita, S
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 860, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Radiol, Fujita, Japan
[3] Kyushu Univ, Fac Med, Dept Radiol, Fukuoka 812, Japan
[4] Nagasaki Univ, Sch Med, Dept Radiol, Nagasaki 852, Japan
[5] Fukuoka Univ, Sch Med, Dept Radiol, Fukuoka 81401, Japan
[6] Kurume Univ, Sch Med, Dept Radiol, Kurume, Fukuoka 830, Japan
[7] Natl Cardiovasc Ctr, Dept Radiol, Osaka, Japan
关键词
aneurysm; CT; intracranial; MR; cerebral blood vessels; computed tomography (CT); three-dimensional;
D O I
10.1148/radiology.211.2.r99ma02497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT;angiography may be a noninvasive technique;for; detection of asymptomatic unruptured or ruptured aneurysms.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 21 条
  • [1] ALBERICO RA, 1995, AM J NEURORADIOL, V16, P1571
  • [2] BrantZawadzki M, 1997, AM J NEURORADIOL, V18, P1021
  • [3] Fleiss J. L, 1981, STAT METHODS RATES P, P212
  • [4] PRACTICAL ISSUES OF EXPERIMENTAL ROC ANALYSIS - SELECTION OF CONTROLS
    GUR, D
    KING, JL
    ROCKETTE, HE
    BRITTON, CA
    THAETE, FL
    HOY, RJ
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (05) : 583 - 586
  • [5] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [6] HEINZ ER, 1995, AM J NEURORADIOL, V16, P1579
  • [7] Hope JKA, 1996, AM J NEURORADIOL, V17, P439
  • [8] CT angiography with volume rendering: Advantages and applications in splanchnic vascular imaging
    Johnson, PT
    Heath, DG
    Kuszyk, BS
    Fishman, EK
    [J]. RADIOLOGY, 1996, 200 (02) : 564 - 568
  • [9] KATADA K, 1990, RADIOLOGY S, V177, P364
  • [10] Intracranial aneurysms: Diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images
    Korogi, Y
    Takahashi, M
    Mabuchi, N
    Nakagawa, T
    Fujiwara, S
    Horikawa, Y
    Miki, H
    OUchi, T
    Shiga, H
    Shiokawa, Y
    Watabe, T
    Furuse, M
    [J]. RADIOLOGY, 1996, 199 (01) : 199 - 207