Intracranial aneurysms: Detection with three-dimensional CT angiography with volume rendering - Comparison with conventional angiographic and surgical findings

被引:142
作者
Korogi, Y
Takahashi, M
Katada, K
Ogura, Y
Hasuo, K
Ochi, M
Utsunomiya, H
Abe, T
Imakita, S
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 860, Japan
[2] Fujita Hlth Univ, Sch Med, Dept Radiol, Fujita, Japan
[3] Kyushu Univ, Fac Med, Dept Radiol, Fukuoka 812, Japan
[4] Nagasaki Univ, Sch Med, Dept Radiol, Nagasaki 852, Japan
[5] Fukuoka Univ, Sch Med, Dept Radiol, Fukuoka 81401, Japan
[6] Kurume Univ, Sch Med, Dept Radiol, Kurume, Fukuoka 830, Japan
[7] Natl Cardiovasc Ctr, Dept Radiol, Osaka, Japan
关键词
aneurysm; CT; intracranial; MR; cerebral blood vessels; computed tomography (CT); three-dimensional;
D O I
10.1148/radiology.211.2.r99ma02497
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT;angiography may be a noninvasive technique;for; detection of asymptomatic unruptured or ruptured aneurysms.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 21 条
  • [11] CT ANGIOGRAPHY WITH VOLUME RENDERING - IMAGING FINDINGS
    KUSZYK, BS
    HEATH, DG
    NEY, DR
    BLUEMKE, DA
    URBAN, BA
    CHAMBERS, TP
    FISHMAN, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 445 - 448
  • [12] DETECTION AND ASSESSMENT OF INTRACRANIAL ANEURYSMS - VALUE OF CT ANGIOGRAPHY WITH SHADED-SURFACE DISPLAY
    LIANG, EY
    CHAN, M
    HSIANG, JHK
    WALKDEN, SB
    POON, WS
    LAM, WWM
    METREWELI, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1497 - 1502
  • [14] METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
  • [15] Ogawa T, 1996, AM J NEURORADIOL, V17, P447
  • [16] OGURA Y, 1995, NEURORADIOLOGY S, V37, pS74
  • [17] Ogura Yuko, 1994, Nippon Acta Radiologica, V54, P965
  • [18] THE USE OF CONTINUOUS AND DISCRETE CONFIDENCE JUDGMENTS IN RECEIVER OPERATING CHARACTERISTIC STUDIES OF DIAGNOSTIC-IMAGING TECHNIQUES
    ROCKETTE, HE
    GUR, D
    METZ, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (02) : 169 - 172
  • [19] EVALUATION OF CEREBRAL ANEURYSMS WITH HELICAL CT - CORRELATION WITH CONVENTIONAL ANGIOGRAPHY AND MR-ANGIOGRAPHY
    SCHWARTZ, RB
    TICE, HM
    HOOTEN, SM
    HSU, LG
    STIEG, PE
    [J]. RADIOLOGY, 1994, 192 (03) : 717 - 722
  • [20] Shrier DA, 1997, AM J NEURORADIOL, V18, P1011