Computed radiography in neonatal and pediatric intensive care units: A comparison of 2.5 K x 2 K soft-copy images vs digital hard-copy film

被引:8
作者
Brill, PW
Winchester, P
Cahill, P
Lesser, M
Durfee, SM
Giess, CS
Auld, PAM
Greenwald, B
机构
[1] N SHORE UNIV HOSP,DIV BIOSTAT,MANHASSET,NY 11030
[2] CORNELL UNIV,MED CTR,NEW YORK HOSP,DEPT PEDIAT,NEW YORK,NY 11021
关键词
D O I
10.1007/BF01395709
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective. The goal of the study was to determine whether soft-copy images on high-resolution monitors (2.5 K x 2 K) are suitable for primary interpretation of images from pediatric and neonatal intensive care units. The hypotheses were that hard and soft images yield similar diagnostic information, and that both residents and faculty radiologists can use monitors effectively. Previous reports have produced conflicting results; the need for larger sample sizes has been empha sized. Materials and methods. One thousand one hundred and four images produced by computed radiography using the Kodak Ectascan Imagelink system were prospectively analyzed by two pediatric radiologists, one reading hard copy and the other soft copy of the same images. Bias was controlled by equal distribution of modalities between observers and by daily alternation of modality. Hard- and soft-copy observations of presence or absence of nine specific tubes and nine specific diagnostic findings were compared. Interobserver differences between pediatric radiologists and radiology residents were studied on additional images. The kappa statistic was used to evaluate the level of agreement for all observations. Results. There was excellent agreement between hard and soft copy interpretation for each tube and diagnostic finding (kappa values 0.93-1.0) and excellent interobserver agreement between two pediatric radiologists (kappa values 0.84-1.0), The level of agreement between radiology residents and pediatric radiologist was excellent for the most objective findings. All results were statistically significant (p < 0.001). Conclusion. High resolution soft-copy images are suitable for primary interpretation in patients in pediatric and neonatal intensive care units.
引用
收藏
页码:333 / 336
页数:4
相关论文
共 9 条
  • [1] DIGITAL IMAGING WITH A PHOTOSTIMULABLE PHOSPHOR IN THE CHEST OF NEWBORNS
    COHEN, MD
    KATZ, BP
    KALASINSKI, LA
    WHITE, SJ
    SMITH, JA
    LONG, B
    [J]. RADIOLOGY, 1991, 181 (03) : 829 - 832
  • [2] VOLUME DETECTION THRESHOLD - QUANTITATIVE COMPARISON OF COMPUTED RADIOGRAPHY AND SCREEN-FILM RADIOGRAPHY IN DETECTION OF PNEUMOTHORACES IN AN ANIMAL-MODEL THAT SIMULATES THE NEONATE
    DON, S
    COHEN, MD
    KRUGER, RA
    WINKLER, TA
    KATZ, BP
    LI, W
    DREESEN, RG
    KENNAN, N
    TARVER, R
    KLATTE, EC
    [J]. RADIOLOGY, 1995, 194 (03) : 727 - 730
  • [3] FAJARDO LL, 1989, AJR, V152, P474
  • [4] HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION
    FRANK, MS
    JOST, RG
    MOLINA, PL
    ANDERSON, DJ
    SOLOMON, SL
    WHITMAN, RA
    MOORE, SM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 473 - 477
  • [5] KEHLER M, 1990, ACTA RADIOL, V31, P47
  • [6] ISSUES IN THE USE OF KAPPA
    KER, M
    [J]. INVESTIGATIVE RADIOLOGY, 1991, 26 (01) : 78 - 83
  • [7] RECEIVER-OPERATING-CHARACTERISTIC STUDY OF CHEST RADIOGRAPHS IN CHILDREN - DIGITAL HARD-COPY FILM VS 2K X 2K SOFT-COPY IMAGES
    RAZAVI, M
    SAYRE, JW
    TAIRA, RK
    SIMONS, M
    HUANG, HK
    CHUANG, KS
    RAHBAR, G
    KANGARLOO, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (02) : 443 - 448
  • [8] COMPARISON OF HARD-COPY AND SOFT-COPY DIGITAL CHEST IMAGES WITH DIFFERENT MATRIX SIZES FOR MANAGING CORONARY-CARE UNIT PATIENTS
    STECKEL, RJ
    BATRA, P
    JOHNSON, S
    SAYRE, J
    BROWN, K
    HAKER, K
    YOUNG, D
    ZUCKER, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (04) : 837 - 841
  • [9] DIGITAL RADIOGRAPHY AND CONVENTIONAL IMAGING OF THE CHEST - A COMPARISON OF OBSERVER PERFORMANCE
    THAETE, FL
    FUHRMAN, CR
    OLIVER, JH
    BRITTON, CA
    CAMPBELL, WI
    FEIST, JH
    STRAUB, WH
    DAVIS, PL
    PLUNKETT, MB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (03) : 575 - 581