DIGITAL RADIOGRAPHY AND CONVENTIONAL IMAGING OF THE CHEST - A COMPARISON OF OBSERVER PERFORMANCE

被引:60
作者
THAETE, FL [1 ]
FUHRMAN, CR [1 ]
OLIVER, JH [1 ]
BRITTON, CA [1 ]
CAMPBELL, WI [1 ]
FEIST, JH [1 ]
STRAUB, WH [1 ]
DAVIS, PL [1 ]
PLUNKETT, MB [1 ]
机构
[1] ABBOTT NW HOSP,DEPT RADIOL,MINNEAPOLIS,MN 55407
关键词
D O I
10.2214/ajr.162.3.8109499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare observer performance in interpreting high-quality, digitally acquired computed radiographs of the chest displayed on either laser-printed radiographs or a workstation with observer performance in interpreting conventional chest radiographs. SUBJECTS AND METHODS. We performed a receiver-operating-characteristic study in which the presence or absence of five abnormalities was determined by nine experienced radiologists on 310 posteroanterior radiographs of the chest displayed in three forms: conventional radiographs, laser-printed films of digital radiographs, and digital radiographs on a high-resolution workstation. RESULTS. The results of our study suggest that observer performance with laser-printed films of digital radiographs obtained with high-resolution (4K x 5K), high-contrast sensitivity (12 bits) and appropriate exposure is comparable to observer performance with conventional radiographs. Observer performance with digital radiographs displayed on the workstation was found to be significantly lower for abnormalities that contained high-frequency and low-contrast information (e.g., interstitial disease and pneumothorax). CONCLUSION. Computed radiography technology can produce image quality that is adequate for interpreting posteroanterior radiographs of the chest. Observer performance is not as good when radiographs displayed on workstations are used to diagnose specific abnormalities.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 23 条
[1]   CLINICAL-EVALUATION OF A MEDICAL IMAGE MANAGEMENT-SYSTEM FOR CHEST IMAGES [J].
ARENSON, RL ;
SESHADRI, SB ;
KUNDEL, HL ;
DESIMONE, D ;
VANDERVOORDE, F ;
GEFTER, WB ;
EPSTEIN, DM ;
MILLER, WT ;
ARONCHICK, JM ;
SIMSON, MB ;
LANKEN, PN ;
KHALSA, S ;
BRIKMAN, I ;
DAVEY, M ;
BRISBON, N .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (01) :55-59
[2]  
CHO PS, 1989, P SPIE, V93, P387
[3]   DIGITIZED FILM RADIOGRAPHY [J].
COOK, LT ;
GIGER, ML ;
WETZEL, LH ;
MURPHEY, MD ;
BATNITZKY, S .
INVESTIGATIVE RADIOLOGY, 1989, 24 (11) :910-916
[4]   CHEST RADIOGRAPHY - COMPARISON OF HIGH-RESOLUTION DIGITAL DISPLAYS WITH CONVENTIONAL AND DIGITAL FILM [J].
COX, GG ;
COOK, LT ;
MCMILLAN, JH ;
ROSENTHAL, SJ ;
DWYER, SJ .
RADIOLOGY, 1990, 176 (03) :771-776
[5]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[6]   HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION [J].
FRANK, MS ;
JOST, RG ;
MOLINA, PL ;
ANDERSON, DJ ;
SOLOMON, SL ;
WHITMAN, RA ;
MOORE, SM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :473-477
[7]   DIGITAL IMAGING OF THE CHEST [J].
FRASER, RG ;
SANDERS, C ;
BARNES, GT ;
MACMAHON, H ;
GIGER, ML ;
DOI, K ;
TEMPLETON, AW ;
COX, GG ;
DWYER, SJ ;
MERRITT, CRB ;
JONES, JP .
RADIOLOGY, 1989, 171 (02) :297-307
[8]   STORAGE PHOSPHOR RADIOGRAPHS VS CONVENTIONAL FILMS - INTERPRETERS PERCEPTIONS OF DIAGNOSTIC QUALITY [J].
FUHRMAN, CR ;
GUR, D ;
GOOD, B ;
ROCKETTE, H ;
COOPERSTEIN, LA ;
FEIST, JH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :1011-1014
[9]  
GOOD WF, 1990, P SOC PHOTO-OPT INS, V1234, P105, DOI 10.1117/12.18950
[10]   PNEUMOTHORAX AND OTHER LUNG-DISEASES - EFFECT OF ALTERED RESOLUTION AND EDGE ENHANCEMENT ON DIAGNOSIS WITH DIGITIZED RADIOGRAPHS [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
TIKOFSKY, RS ;
HOFFMANN, RG .
RADIOLOGY, 1988, 167 (01) :83-88