Cd(II) sensing in water using novel aromatic iminodiacetate based fluorescent chemosensors

被引:165
作者
Gunnlaugsson, T [1 ]
Lee, TC
Parkesh, R
机构
[1] Trinity Coll Dublin, Dept Chem, Dublin 2, Ireland
[2] Royal Coll Surgeons Ireland, Dept Anat, Dublin 2, Ireland
关键词
D O I
10.1021/ol035484t
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
[GRAPHIC] Compounds 1 and 2 were designed as fluorescent chemosensors for Cd(II). For both, a selective determination of Cd(II) over Zn(II) was achieved. The fluorescence emission of both was pH-independent and switched off between pH 3-11 in 100% water. Whereas the recognition of Cd(II) at pH 7.4 gave rise to the formation of charge-transfer complexes (exciplexes) for both (lambda(max) ca. 500 and 506 nm, respectively), the recognition of Zn(II) only switched on the (monomeric) anthracene emission of 2, while for 1 it was red-shifted (lambda(max) = 468 nm).
引用
收藏
页码:4065 / 4068
页数:4
相关论文
共 51 条
[21]   Simultaneous determination of cadmium and zinc using a fiber optic device and fluorescence spectrometry [J].
Ertas, N ;
Akkaya, EU ;
Ataman, OY .
TALANTA, 2000, 51 (04) :693-699
[22]   The design of luminescent sensors for anions and ionisable analytes [J].
Fabbrizzi, L ;
Licchelli, M ;
Rabaioli, G ;
Taglietti, A .
COORDINATION CHEMISTRY REVIEWS, 2000, 205 :85-108
[23]   Delayed lanthanide luminescence sensing of aromatic carboxylates using heptadentate triamide Tb(III) cyclen complexes: the recognition of salicylic acid in water [J].
Gunnlaugsson, T ;
Harte, AJ ;
Leonard, JP ;
Nieuwenhuyzen, M .
CHEMICAL COMMUNICATIONS, 2002, (18) :2134-2135
[24]   Luminescent molecular logic gates:: the two-input inhibit (INH) function [J].
Gunnlaugsson, T ;
Mac Dónail, DA ;
Parker, D .
CHEMICAL COMMUNICATIONS, 2000, (01) :93-94
[25]   Lanthanide macrocyclic quinolyl conjugates as luminescent molecular-level devices [J].
Gunnlaugsson, T ;
Mac Dónaill, DA ;
Parker, D .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (51) :12866-12876
[26]   Dual responsive chemosensors for anions: the combination of fluorescent PET (photoinduced electron transfer) and colorimetric chemosensors in a single molecule [J].
Gunnlaugsson, T ;
Kruger, PE ;
Lee, TC ;
Parkesh, R ;
Pfeffer, FM ;
Hussey, GM .
TETRAHEDRON LETTERS, 2003, 44 (35) :6575-6578
[27]   Fluorescent photoinduced electron transfer (PET) sensing of anions using charge neutral chemosensors [J].
Gunnlaugsson, T ;
Davis, AP ;
Glynn, M .
CHEMICAL COMMUNICATIONS, 2001, (24) :2556-2557
[28]   Fluorescent sensing of pyrophosphate and bis-carboxylates with charge neutral PET chemosensors [J].
Gunnlaugsson, T ;
Davis, AP ;
O'Brien, JE ;
Glynn, M .
ORGANIC LETTERS, 2002, 4 (15) :2449-2452
[29]   Synthesis and evaluation of colorimetric chemosensors for monitoring sodium and potassium ions in the intracellular concentration range [J].
Gunnlaugsson, T ;
Leonard, JP .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 2002, (12) :1980-1985
[30]   A novel fluorescent photoinduced electron transfer (PET) sensor for lithium [J].
Gunnlaugsson, T ;
Bichell, B ;
Nolan, C .
TETRAHEDRON LETTERS, 2002, 43 (28) :4989-4992