Fiducial-less alignment of cryo-sections

被引:47
作者
Castano-Diez, Daniel [1 ]
Al-Amoudi, Ashraf [1 ]
Glynn, Anne-Marie [1 ]
Seybert, Anja [1 ]
Frangakis, Achilleas S. [1 ]
机构
[1] European Mol Biol Lab, D-69117 Heidelberg, Germany
关键词
electron tomography; image processing; CEMOVIS;
D O I
10.1016/j.jsb.2007.04.014
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron tomography of vitreous sections is currently the most promising technique for visualizing arbitrary regions of eukaryotic cells or tissue at molecular resolution. Despite significant progress in the sample preparation techniques over the past few years, the three dimensional reconstruction using electron tomography is not as simple as in plunge frozen samples for various reasons, but mainly due to the effects of irradiation on the sections and the resulting poor alignment. Here, we present a new algorithm, which can provide a useful three-dimensional marker model after investigation of hundreds to thousands of observations calculated using local cross-correlation throughout the tilt series. The observations are chosen according to their coherence to a particular model and assigned to virtual markers. Through this type of measurement a merit figure can be calculated, precisely estimating the quality of the reconstruction. The merit figures of this alignment method are comparable to those obtained with plunge frozen samples using fiducial gold markers. An additional advantage of the algorithm is the implicit detection of areas in the sections that behave as rigid bodies and can thus be properly reconstructed. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:413 / 423
页数:11
相关论文
共 23 条
[1]   Cutting artefacts and cutting process in vitreous sections for cryo-electron microscopy [J].
Al-Amoudi, A ;
Studer, D ;
Dubochet, J .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 150 (01) :109-121
[2]   Cryo-electron microscopy of vitreous sections [J].
Al-Amoudi, A ;
Chang, JJ ;
Leforestier, A ;
McDowall, A ;
Salamin, LM ;
Norlén, LPO ;
Richter, K ;
Blanc, NS ;
Studer, D ;
Dubochet, J .
EMBO JOURNAL, 2004, 23 (18) :3583-3588
[3]   Electron beam-induced changes in vitreous sections of biological samples [J].
Blanc, NS ;
Studer, D ;
Ruhl, K ;
Dubochet, J .
JOURNAL OF MICROSCOPY, 1998, 192 :194-201
[4]   Visualization of cell microtubules in their native state [J].
Bouchet-Marquis, Cedric ;
Zuber, Benoit ;
Glynn, Anne-Marie ;
Eltsov, Mikhail ;
Grabenbauer, Markus ;
Goldie, Kenneth N. ;
Thomas, Daniel ;
Frangakis, Achilleas S. ;
Dubochet, Jacques ;
Chretien, Denis .
BIOLOGY OF THE CELL, 2007, 99 (01) :45-53
[5]   Automatic alignment of transmission electron microscope tilt series without fiducial markers [J].
Brandt, S ;
Heikkonen, J ;
Engelhardt, P .
JOURNAL OF STRUCTURAL BIOLOGY, 2001, 136 (03) :201-213
[6]   Multiphase method for automatic alignment of transmission electron microscope images using markers [J].
Brandt, S ;
Heikkonen, J ;
Engelhardt, P .
JOURNAL OF STRUCTURAL BIOLOGY, 2001, 133 (01) :10-22
[7]   A resolution criterion for electron tomography based on cross-validation [J].
Cardone, G ;
Grünewald, K ;
Steven, AC .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 151 (02) :117-129
[8]   Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axis [J].
Díez, DC ;
Seybert, A ;
Frangakis, AS .
JOURNAL OF STRUCTURAL BIOLOGY, 2006, 154 (02) :195-205
[9]   CRYO-ELECTRON MICROSCOPY OF VITRIFIED SPECIMENS [J].
DUBOCHET, J ;
ADRIAN, M ;
CHANG, JJ ;
HOMO, JC ;
LEPAULT, J ;
MCDOWALL, AW ;
SCHULTZ, P .
QUARTERLY REVIEWS OF BIOPHYSICS, 1988, 21 (02) :129-228
[10]   Three-dimensional imaging of biological complexity [J].
Frank, J ;
Wagenknecht, T ;
McEwen, BF ;
Marko, M ;
Hsieh, CE ;
Mannella, CA .
JOURNAL OF STRUCTURAL BIOLOGY, 2002, 138 (1-2) :85-91