Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber

被引:100
作者
Wu, Lina
Zhang, Xueji
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Educ Minist China, Nanjing 210093, Peoples R China
[2] Univ S Florida, Dept Chem, Tampa, FL 33620 USA
基金
中国国家自然科学基金;
关键词
biosensors; carbon nanofiber; dissolved oxygen; glucose; electrochemistry;
D O I
10.1016/j.bios.2007.06.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work shows excellent catalytic activity of soluble carbon nanofiber (CNF), which was obtained with a simple nitric acid treatment, toward the electroreduction of dissolved oxygen at a low operating potential. Thus the CNF was applied in the construction of amperometric biosensors for oxidase substrates using glucose oxidase as a model. The good dispersion of CNF led to convenient preparation and acceptable repeatability of the proposed sensors. UV-vis spectra, Fourier transform infrared spectra, X-ray photoelectron spectra and titration curves demonstrated that the good dispersion resulted from the large numbers of surface oxygen-rich groups produced in the treatment process. The membrane of CNF showed good stability and provided fast response to dissolved oxygen with a linear range from 0.1 to 78 mu M and detection limit of 0.07 mu M. The proposed glucose biosensor could monitor glucose ranging from 10 to 350 mu M with detection limit of 2.5 mu M and sensitivity of 36.3 nA cm(-2) mu M-1. The coefficients of variation for intra-assay were 4.7 and 3.2% at glucose concentrations of 20 and 210 mu M, respectively. The use of a low operating potential (-0.3 V) and Nafion membrane produced good selectivity toward the glucose detection. CNF-based biosensors would provide wide range of bioelectrochemical applications in different fields. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:479 / 484
页数:6
相关论文
共 43 条
[1]   Distinct differences in partial oxygen pressure at micrometer ranges in the rat hippocampal region [J].
Andreasen, A ;
Danscher, G ;
Juhl, S ;
Stoltenberg, M ;
Revsbech, NP ;
Jensen, H ;
Jensen, KB .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 72 (01) :15-21
[2]   Carbon nanofiber-copper composite powder prepared by electrodeposition [J].
Arai, S ;
Endo, M .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (09) :797-799
[3]   Carbon nanotube actuators [J].
Baughman, RH ;
Cui, CX ;
Zakhidov, AA ;
Iqbal, Z ;
Barisci, JN ;
Spinks, GM ;
Wallace, GG ;
Mazzoldi, A ;
De Rossi, D ;
Rinzler, AG ;
Jaschinski, O ;
Roth, S ;
Kertesz, M .
SCIENCE, 1999, 284 (5418) :1340-1344
[4]   In situ detection of cytochrome c adsorption with single walled carbon nanotube device [J].
Boussaad, S ;
Tao, NJ ;
Zhang, R ;
Hopson, T ;
Nagahara, LA .
CHEMICAL COMMUNICATIONS, 2003, (13) :1502-1503
[5]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[6]   Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhang, Lingyan ;
Wang, Na ;
Li, Xuelian .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1268-1274
[7]   Growth of carbon nanofibers on tipless cantilevers for high resolution topography and magnetic force imaging [J].
Cui, H ;
Kalinin, SV ;
Yang, X ;
Lowndes, DH .
NANO LETTERS, 2004, 4 (11) :2157-2161
[8]   Electrocatalytic reduction of oxygen by a platinum nanoparticle/carbon nanotube composite electrode [J].
Cui, HF ;
Ye, JS ;
Zhang, WD ;
Wang, J ;
Sheu, FS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 577 (02) :295-302
[9]   Aligned carbon nanotube-DNA electrochemical sensors [J].
He, PG ;
Dai, LM .
CHEMICAL COMMUNICATIONS, 2004, (03) :348-349
[10]   Fabrication and characterization of polyaniline coated carbon nanofiber for supercapacitor [J].
Jang, J ;
Bae, J ;
Choi, M ;
Yoon, SH .
CARBON, 2005, 43 (13) :2730-2736