Species-specific isotope-ratio measurements of volatile tin and antimony compounds using capillary GC-ICP-time-of-flight MS

被引:24
作者
Haas, K
Feldmann, J
Wennrich, R
Stärk, HJ
机构
[1] Univ Aberdeen, Dept Chem, Old Aberdeen AB24 3UE, Scotland
[2] UFZ Helmholtz Ctr Environm Res, Dept Analyt Chem, D-04318 Leipzig, Germany
关键词
D O I
10.1007/s002160100797
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical performance of an axial inductively-coupled-plasma time-of-flight mass spectrometer (ICP-TOFMS) as a detector for fast transient chromatographic signals resulting from the coupling to capillary gas chromatography (CGC) was investigated. A cryotrapping GC-ICP-TOFMS method for the determination of volatile metal(loid) compounds (VOMs) in gases was used and the suitability of the TOF mass analyzer for multielemental speciation analysis and multi-isotope ratio determinations was studied in terms of accuracy and precision. Isotope ratios Sn-118/Sn-120 and Sb-121/Sb-123 have been determined in in-house gas standard atmospheres in Tedlar bags at two different levels (100 pg and I ng) for different elemental species (SnH4, MeSnH3, Me2SnH2, Me3SnH, BuSnH3, SbH3, and MeSbH2). A limitation arising from counting statistics in both detection modes could be shown. A solution containing rhodium (10 ng mL(-1)) and cadmium (40 ng mL(-1)) was introduced simultaneously to the GC outlet. Rhodium acts as a continuous internal standard and Cd is used for mass-bias correction (by measuring the Cd-111/Cd-113 ratio). The detection system in both pulse counting and analog mode was examined. The best attainable precision was established for Me2SnH2 (analog mode, 12 replicates, 1 ng, RSD 0.34%, accuracy 0.31%) whereas most other species ranged between 0.4 and 0.5% RSD if higher concentrations were used. The limitations of the pulse counting system are clearly seen, with peak heights of more than 2000 counts reaching saturation (for an integration time of 100 ms), which reduces the accuracy of isotope ratio determinations. A dozen VOM could be detected in an aged landfill gas sample; several unidentified Sn compounds were present. Although their isotope ratios are within the confidence value of the standards, it is not yet clear if the acquired precision is good enough to identify isotopic fractionation of metal(loid)s through biovolatilization processes. With the precision achieved, the combination of cryotrapping GC and ICP-TOFMS is a powerful tool for monitoring volatile multi-element species in multi-tracer experiments and isotope dilution methodology.
引用
收藏
页码:587 / 596
页数:10
相关论文
共 20 条
[1]   Optimization of a laser ablation-inductively coupled plasma "time of flight" mass spectrometry system for short transient signal acquisition [J].
Bleiner, D ;
Hametner, K ;
Günther, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01) :37-44
[2]   Mass spectrometry with plasma sources at atmospheric pressure - state-of-the-art and some developmental trends [J].
Broekaert, JAC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (01) :15-22
[3]   Rapid simultaneous multielemental speciation by capillary electrophoresis coupled to inductively coupled plasma time-of-flight mass spectrometry [J].
Costa-Fernández, JM ;
Bings, NH ;
Leach, AM ;
Hieftje, GM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1063-1067
[4]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[5]  
CURRELL G, 1996, INSTRUMENTATION
[6]   METHYLATED ANTIMONY(V) COMPOUNDS - SYNTHESIS, HYDRIDE GENERATION PROPERTIES AND IMPLICATIONS FOR AQUATIC SPECIATION [J].
DODD, M ;
GRUNDY, SL ;
REIMER, KJ ;
CULLEN, WR .
APPLIED ORGANOMETALLIC CHEMISTRY, 1992, 6 (02) :207-211
[7]   Determination of Ni(CO)4, Fe(CO)5, Mo(CO)6, and W(CO)6 in sewage gas by using cryotrapping gas chromatography inductively coupled plasma mass spectrometry [J].
Feldmann, J .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (01) :33-37
[8]   OCCURRENCE OF VOLATILE METAL AND METALLOID SPECIES IN LANDFILL AND SEWAGE GASES [J].
FELDMANN, J ;
HIRNER, AV .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1995, 60 (2-4) :339-359
[9]   Metal(loid)organic compounds in geothermal gases and waters [J].
Hirner, AV ;
Feldmann, J ;
Krupp, E ;
Grümping, R ;
Goguel, R ;
Cullen, WR .
ORGANIC GEOCHEMISTRY, 1998, 29 (5-7) :1765-1778
[10]   MASS-SPECTROMETRY ON THE CHROMATOGRAPHIC TIME SCALE - REALISTIC EXPECTATIONS [J].
HOLLAND, JF ;
ENKE, CG ;
ALLISON, J ;
STULTS, JT ;
PINKSTON, JD ;
NEWCOME, B ;
WATSON, JT .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :A997-&