Dependence of dopamine calibration factors on media Ca2+ and Mg2+ at carbon-fiber microelectrodes used with fast-scan cyclic voltammetry

被引:42
作者
Kume-Kick, J
Rice, ME
机构
[1] NYU, Med Ctr, Dept Physiol, New York, NY 10016 USA
[2] NYU, Med Ctr, Dept Neurosci, New York, NY 10016 USA
[3] NYU, Med Ctr, Dept Neurosurg, New York, NY 10016 USA
关键词
dopamine; voltammetry; carbon-fiber microelectrodes; electrode calibration; fast-scan cyclic voltammetry; calcium; substantia nigra;
D O I
10.1016/S0165-0270(98)00087-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Carbon-fiber microelectrodes and voltammetric methods have been used extensively for the detection of dopamine in brain tissue in vivo and in vitro. Voltammetric microelectrodes are often calibrated in non-physiological media, like phosphate-buffered saline, rather than in oxygenated physiological media. Here, we determined dopamine calibration factors (nA mu M-1) in several defined solutions for two types of carbon-fiber electrode used with fast-scan cyclic voltammetry. For both electrode types, dopamine calibration factors, and thus electrode sensitivities, were 2-3-fold higher in phosphate- or HERES-buffered saline than in a bicarbonate-based artificial CSF (ACSF) that reflected that normal ionic composition of brain extracellular fluid. Removal of Ca2+ and Mg2+ from ACSF eliminated this difference. Because extracellular Ca2+ concentration ([Ca2+](o)) can fall under stimulation conditions used to elicit dopamine release, we also evaluated the size of stimulated [Ca2+](o) shifts in guinea pig midbrain slices using ion-selective microelectrodes. The [Ca2+](o) decreases were less than 100 mu M, which was well below the mM decreases observed to alter DA sensitivity. Consequently, calibration data obtained in normal physiological solutions should be valid under conditions of mild stimulation. Moreover, calibration in divalent cation-free media will cause calculated DA levels to be underestimated and should be avoided, unless appropriate for a given experimental paradigm. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 31 条
[1]   INVIVO ELECTROCHEMICAL MEASUREMENTS IN THE CNS [J].
ADAMS, RN .
PROGRESS IN NEUROBIOLOGY, 1990, 35 (04) :297-311
[2]   QUANTITATIVE IONOPHORESIS OF CATECHOLAMINES USING MULTIBARREL CARBON-FIBER MICROELECTRODES [J].
ARMSTRONGJAMES, M ;
FOX, K ;
KRUK, ZL ;
MILLAR, J .
JOURNAL OF NEUROSCIENCE METHODS, 1981, 4 (04) :385-406
[3]  
BOULTON AA, 1995, NEUROMETHODS, V27
[4]   APPLICATION OF FAST CYCLIC VOLTAMMETRY TO MEASUREMENT OF ELECTRICALLY EVOKED DOPAMINE OVERFLOW FROM BRAIN-SLICES INVITRO [J].
BULL, DR ;
PALIJ, P ;
SHEEHAN, MJ ;
MILLAR, J ;
STAMFORD, JA ;
KRUK, ZL ;
HUMPHREY, PPA .
JOURNAL OF NEUROSCIENCE METHODS, 1990, 32 (01) :37-44
[5]  
CHUTKOW JG, 1988, NEUROMETHODS, V9, P691
[6]   Heterogeneity of electrically evoked dopamine release and reuptake in substantia nigra, ventral tegmental area, and striatum [J].
Cragg, SJ ;
Rice, ME ;
Greenfield, SA .
JOURNAL OF NEUROPHYSIOLOGY, 1997, 77 (02) :863-873
[8]  
CULLCANDY SG, 1987, NATURE, V325, P527
[9]  
GARRIS PA, 1994, J NEUROSCI, V14, P442
[10]   NAFION-COATED ELECTRODES WITH HIGH SELECTIVITY FOR CNS ELECTROCHEMISTRY [J].
GERHARDT, GA ;
OKE, AF ;
NAGY, G ;
MOGHADDAM, B ;
ADAMS, RN .
BRAIN RESEARCH, 1984, 290 (02) :390-395