Electroosmotic properties of microfluidic channels composed of poly(dimethylsiloxane)

被引:181
作者
Ren, XQ
Bachman, M
Sims, C
Li, GP [1 ]
Allbritton, N
机构
[1] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Elect & Comp Engn, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Physiol & Biophys, Irvine, CA 92697 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 762卷 / 02期
关键词
electroosmotic mobility; microfluidic channels; poly(dimethylsiloxane);
D O I
10.1016/S0378-4347(01)00327-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic devices fabricated from polymers exhibit great potential in biological analyses. Poly(dimethylsiloxane) (PDMS) has shown promise as a substrate for rapid prototyping of devices. Despite this, disagreement exists in the literature as to the ability of PDMS to support electroosmotic (EO) flow and the stability of that flow over time. We demonstrate that in low ionic strength solutions near neutral in pH, oxidized PDMS had a four-fold greater EO mobility (mu (eo)) compared to native PDMS. The greater mu (eo) was maintained irrespective of whether glass or PDMS was used as a support forming one side of the channel, This enhanced mu (eo) was preserved as long as the channels were filled with an aqueous solution. Upon exposure of the channels to air, the mobility decreased by a factor of two with a half-life of 9 h. The EO properties of the air-exposed, oxidized PDMS were regenerated by exposure to strong base. High ionic strength, neutral in pH buffers compatible with living eukaryotic cells diminished the EO flow in the oxidized PDMS devices to a much greater extent than in the native PDMS devices. For analyses utilizing intact and living cells, oxidation of PDMS may not be an effective strategy to substantially increase the mu (eo). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 34 条
  • [1] Bayer H, 1996, J MICROCOLUMN SEP, V8, P479
  • [2] Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
  • [3] 2-7
  • [4] SURFACE RECOVERY OF SILICONE-RUBBER USED FOR HV OUTDOOR INSULATION
    CHANG, JW
    GORUR, RS
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1994, 1 (06) : 1039 - 1046
  • [5] Microfluidic networks for chemical patterning of substrate: Design and application to bioassays
    Delamarche, E
    Bernard, A
    Schmid, H
    Bietsch, A
    Michel, B
    Biebuyck, H
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (03) : 500 - 508
  • [6] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984
  • [7] Micromachining in plastics using X-ray lithography for the fabrication of micro-electrophoresis devices
    Ford, SM
    Davies, J
    Kar, B
    Qi, SD
    McWhorter, S
    Soper, SA
    Malek, CK
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (01): : 13 - 21
  • [8] A microfabricated fluorescence-activated cell sorter
    Fu, AY
    Spence, C
    Scherer, A
    Arnold, FH
    Quake, SR
    [J]. NATURE BIOTECHNOLOGY, 1999, 17 (11) : 1109 - 1111
  • [9] Membrane purification of Cl2 gas I.: Permeabilities as a function of temperature for Cl2, O2, N2, H2 in two types of PDMS membranes
    Hägg, MB
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2000, 170 (02) : 173 - 190
  • [10] Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges
    Hillborg, H
    Gedde, UW
    [J]. POLYMER, 1998, 39 (10) : 1991 - 1998