XAFS and X-MCD spectroscopies with undulator gap scan

被引:26
作者
Rogalev, A [1 ]
Gotte, V [1 ]
Goulon, J [1 ]
Gauthier, C [1 ]
Chavanne, J [1 ]
Elleaume, P [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
EXAFS; X-MCD; spin polarized EXAFS; undulator sources;
D O I
10.1107/S0909049597014702
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The first experimental applications of the undulator gap-scan technique in X-ray absorption spectroscopy are reported. The key advantage of this method is that during EXAFS scans the undulator is permanently tuned to the maximum of its emission peak in order to maximize the photon statistics. In X-MCD or spin-polarized EXAFS studies with a helical undulator of the Hellos type, the polarization rate can also be kept almost constant over a wide energy range.
引用
收藏
页码:989 / 991
页数:3
相关论文
共 9 条
  • [1] CRYSTAL AND MOLECULAR-STRUCTURE OF TETRAGONAL L-CYSTINE
    CHANEY, MO
    STEINRAUF, LK
    [J]. ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE CRYSTAL ENGINEERING AND MATERIALS, 1974, 30 (MAR15): : 711 - 716
  • [2] STATUS OF THE EUROPEAN SYNCHROTRON RADIATION FACILITY INSERTION DEVICES
    CHAVANNE, J
    CHINCHIO, E
    DIOT, M
    ELLEAUME, P
    FRACHON, D
    MARECHAL, X
    MARIAGGI, C
    REVOL, F
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) : 317 - 320
  • [3] HELIOS - A NEW-TYPE OF LINEAR HELICAL UNDULATOR
    ELLEAUME, P
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 : 19 - 26
  • [4] AN ESRF BEAMLINE DEDICATED TO POLARIZATION-SENSITIVE XAS AT LOW EXCITATION-ENERGIES
    ELLEAUME, P
    CHAVANNE, J
    MARECHAL, X
    GOULON, J
    BRAICOVICH, L
    MALGRANGE, C
    EMERICH, H
    MAROT, G
    SUSINI, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2) : 382 - 389
  • [5] MODULATED DETECTION OF MULTIBEAM DICHROISM USING PHOTODIODES
    GAUTHIER, C
    GOUJON, G
    FEITE, S
    MOGUILINE, E
    BRAICOVICH, L
    BROOKES, NB
    GOULON, J
    [J]. PHYSICA B, 1995, 208 (1-4): : 232 - 234
  • [6] Instrumentation developments for X-ray linear and circular dichroism at the ESRF beamline ID12A
    Goulon, J
    Rogalev, A
    Gauthier, C
    Goulon-Ginet, C
    Paste, S
    Signorato, R
    Neumann, C
    Varga, L
    Malgrange, C
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 232 - 238
  • [7] The beamline ID24 at ESRF for energy dispersive X-ray absorption spectroscopy
    Hagelstein, M
    San Miguel, A
    Fontaine, A
    Goulon, J
    [J]. JOURNAL DE PHYSIQUE IV, 1997, 7 (C2): : 303 - 308
  • [8] Spin polarised XAFS of EuS in ferromagnetic and paramagnetic phases
    Rogalev, A
    Goedkoop, JB
    Rogaleva, M
    Gotte, V
    Goulon, J
    [J]. JOURNAL DE PHYSIQUE IV, 1997, 7 (C2): : 465 - 466
  • [9] ROGALEV A, 1998, UNPUB PHYS REV LETT