Thalamic stimulation and functional magnetic resonance imaging: localization of cortical and subcortical activation with implanted electrodes - Technical note

被引:120
作者
Rezai, AR
Lozano, AM
Crawley, AP
Joy, MLG
Davis, KD
Kwan, CL
Dostrovsky, JO
Tasker, RR
Mikulis, DJ
机构
[1] NYU, Med Ctr, Dept Neurosurg, New York, NY 10016 USA
[2] Univ Toronto, Div Neurosurg, Playfair Neurosci Unit, Toronto, ON, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[4] Univ Toronto, Dept Biomed Engn, Toronto, ON, Canada
[5] Univ Toronto, Dept Physiol, Toronto, ON, Canada
关键词
chronic pain; deep brain stimulation; functional magnetic resonance imaging; periventricular gray matter; somatosensory cortex; thalamus;
D O I
10.3171/jns.1999.90.3.0583
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The utility of functional magnetic resonance (fMR) imaging in patients with implanted thalamic electrodes has not yet been determined. The aim of this study was to establish the safety of performing fMR imaging in patients with thalamic deep brain stimulators and to determine the value of fMR imaging in detecting cortical and subcortical activity during stimulation. Functional MR imaging was performed in three patients suffering from chronic pain and two patients with essential tremor. Two of the three patients with pain had undergone electrode implantation in the thalamic sensory ventralis caudalis (Vc) nucleus and the other had undergone electrode implantation in both the Vc and the periventricular gray (PVG) matter. Patients with tremor underwent electrode implantation in the ventralis intermedius (Vim) nucleus. Functional MR imaging was performed during stimulation by using a pulse generator connected to a transcutaneous extension lead. Clinically, Vc stimulation evoked paresthesias in the contralateral body, PVG stimulation evoked a sensation of diffuse internal body warmth, and Vim stimulation caused tremor arrest. Functional images were acquired using a 1.5-tesla MR imaging system. The Vc stimulation at intensities provoking paresthesias resulted in activation of the primary somatosensory cortex (SI). Stimulation at subthreshold intensities failed to activate the SI. Additional stimulation-coupled activation was observed in the thalamus, the secondary somatosensory cortex (SII), and the insula. In contrast, stimulation of the PVG electrode did not evoke paresthesias or activate the SI, but resulted in medial thalamic and cingulate cortex activation. Stimulation in the Vim resulted in thalamic, basal ganglia, and SI activation. An evaluation of the safety of the procedure indicated that significant current could be induced within the electrode if a faulty connecting cable (defective insulation) came in contact with the patient. Simple precautions, such as inspection of wires for fraying and prevention of their contact with the patient, enabled the procedure to be conducted safely. Clinical safely was further corroborated by performing 86 MR studies in patients in whom electrodes had been implanted with no adverse clinical effects. This is the first report of the use of fMR imaging during stimulation with implanted thalamic electrodes. The authors' findings demonstrate that fMR imaging can safely detect the activation of cortical and subcortical neuronal pathways during stimulation and that, stimulation does not interfere with imaging. This approach offers great potential for understanding the mechanisms of action of deep brain stimulation and those underlying pain and tremor generation.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 34 条
[11]   Globus pallidus stimulation activates the cortical motor system during alleviation of parkinsonian symptoms [J].
Davis, KD ;
Taub, E ;
Houle, S ;
Lang, AE ;
Dostrovsky, JO ;
Tasker, RR ;
Lozano, AM .
NATURE MEDICINE, 1997, 3 (06) :671-674
[12]  
DAVIS KD, 1998, NEUROIMAGE, V7, pS997
[13]  
DAVIS KD, 1998, NEUROIMAGE, V7, P439
[14]  
DAVIS KD, 1998, NEUROIMAGE, V7, pS426
[15]  
Dormont D, 1997, AM J NEURORADIOL, V18, P1093
[16]   Fingertip representation in the human somatosensory cortex: An fMRI study [J].
Gelnar, PA ;
Krauss, BR ;
Szeverenyi, NM ;
Apkarian, AV .
NEUROIMAGE, 1998, 7 (04) :261-283
[17]   MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS [J].
GLOVER, GH ;
LEE, AT .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :624-635
[18]   Motion detection and correction in functional MR imaging [J].
Jiang, AP ;
Kennedy, DN ;
Baker, JR ;
Weisskoff, RM ;
Tootell, RBH ;
Woods, RP ;
Benson, RR ;
Kwong, KK ;
Brady, TJ ;
Rosen, BR ;
Belliveau, JW .
HUMAN BRAIN MAPPING, 1995, 3 (03) :224-235
[19]   Somatotopy in the human motor cortex hand area. A high-resolution functional MRI study [J].
Kleinschmidt, A ;
Nitschke, MF ;
Frahm, J .
EUROPEAN JOURNAL OF NEUROSCIENCE, 1997, 9 (10) :2178-2186
[20]   Subthalamic nucleus or internal pallidal stimulation in young onset Parkinson's disease [J].
Krack, P ;
Pollak, P ;
Limousin, P ;
Hoffmann, D ;
Xie, J ;
Benazzouz, A ;
Benabid, AL .
BRAIN, 1998, 121 :451-457