Accuracy and dynamic range of spatial image correlation and cross-correlation spectroscopy

被引:54
作者
Costantino, S
Comeau, JWD
Kolin, DL
Wiseman, PW [1 ]
机构
[1] McGill Univ, Dept Phys, Montreal, PQ, Canada
[2] McGill Univ, Dept Chem, Montreal, PQ, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
D O I
10.1529/biophysj.104.057364
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a comprehensive study of the accuracy and dynamic range of spatial image correlation spectroscopy (ICS) and image cross-correlation spectroscopy (ICCS). We use simulations to model laser scanning microscopy imaging of static subdiffraction limit fluorescent proteins or protein clusters in a cell membrane. The simulation programs allow us to control the spatial imaging sampling variables and the particle population densities and interactions and introduce and vary background and counting noise typical of what is encountered in digital optical microscopy. We systematically calculate how the accuracy of both image correlation methods depends on practical experimental collection parameters and characteristics of the sample. The results of this study provide a guide to appropriately plan spatial image correlation measurements on proteins in biological membranes in real cells. The data presented map regimes where the spatial ICS and ICCS provide accurate results as well as clearly showing the conditions where they systematically deviate from acceptable accuracy. Finally, we compare the simulated data with standard confocal microscopy using live CHO cells expressing the epidermal growth factor receptor fused with green fluorescent protein (GFP/EGFR) to obtain typical values for the experimental variables that were investigated in our study. We used our simulation results to estimate a relative precision of 20% for the ICS measured receptor density of 64 mu m(-2) within a 121 x 98 pixel subregion of a single cell.
引用
收藏
页码:1251 / 1260
页数:10
相关论文
共 24 条
[1]   ON THE MEASUREMENT OF PARTICLE NUMBER AND MOBILITY IN NONIDEAL SOLUTIONS BY FLUORESCENCE CORRELATION SPECTROSCOPY [J].
ABNEY, JR ;
SCALETTAR, BA ;
HACKENBROCK, CR .
BIOPHYSICAL JOURNAL, 1990, 58 (01) :261-265
[2]  
Brock P, 1999, CYTOMETRY, V35, P353, DOI 10.1002/(SICI)1097-0320(19990401)35:4<353::AID-CYTO8>3.0.CO
[3]  
2-M
[4]   An internalization-competent influenza hemagglutinin mutant causes the redistribution of AP-2 to existing coated pits and is colocalized with AP-2 in clathrin free clusters [J].
Brown, CM ;
Roth, MG ;
Henis, YI ;
Petersen, NO .
BIOCHEMISTRY, 1999, 38 (46) :15166-15173
[5]  
Brown CM, 1998, J CELL SCI, V111, P271
[6]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[7]   Fluorescence correlation spectroscopy measures molecular transport in cells [J].
Elson, EL .
TRAFFIC, 2001, 2 (11) :789-796
[8]   Imaging fluorescence correlation spectroscopy: Nonuniform IgE distributions on planar membranes [J].
Huang, ZP ;
Thompson, NL .
BIOPHYSICAL JOURNAL, 1996, 70 (04) :2001-2007
[9]   Statistical accuracy in fluorescence fluctuation experiments [J].
Kask, P ;
Gunther, R ;
Axhausen, P .
EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 1997, 25 (03) :163-169
[10]   STATISTICAL ACCURACY IN FLUORESCENCE CORRELATION SPECTROSCOPY [J].
KOPPEL, DE .
PHYSICAL REVIEW A, 1974, 10 (06) :1938-1945