Rapid monitoring of antibiotics using Raman and surface enhanced Raman spectroscopy

被引:74
作者
Clarke, SJ
Littleford, RE
Smith, WE
Goodacre, R
机构
[1] Univ Manchester, Sch Chem, Manchester M60 1QD, Lancs, England
[2] Univ Wales, Inst Biol Sci, Aberystwyth SY23 3DD, Ceredigion, Wales
[3] Univ Strathclyde, Dept Pure & Appl Chem, Glasgow G1 1XL, Lanark, Scotland
关键词
D O I
10.1039/b502540k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Comparatively few studies have explored the ability of Raman spectroscopy for the quantitative analysis of microbial secondary metabolites in fermentation broths. In this study we investigated the ability of Raman spectroscopy to differentiate between different penicillins and to quantify the level of penicillin in fermentation broths. However, the Raman signal is rather weak, therefore the Raman signal was enhanced using surface enhanced Raman spectroscopy (SERS) employing silver colloids. It was difficult by eye to differentiate between the five different penicillin molecules studied using Raman and SERS spectra, therefore the spectra were analysed by multivariate cluster analysis. Principal components analysis (PCA) clearly showed that SERS rather than the Raman spectra produced reproducible enough spectra to allow for the recovery of each of the different penicillins into their respective five groups. To highlight this further the first five principal components were used to construct a dendrogram using agglomerative clustering, and this again clearly showed that SERS can be used to identify which penicillin molecule was being analysed, despite their molecular similarities. With respect to the quantification of penicillin G it was shown that Raman spectroscopy could be used to quantify the amount of penicillin present in solution when relatively high levels of penicillin were analysed (>50 mM). By contrast, the SERS spectra showed reduced fluorescence, and improved signal to noise ratios from considerably lower concentrations of the antibiotic. This could prove to be advantageous in industry for monitoring low levels of penicillin in the early stages of antibiotic production. In addition, SERS may have advantages for quantifying low levels of high value, low yield, secondary metabolites in microbial processes.
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 26 条
[1]   Raman spectroscopy for process/quality control [J].
Adar, F ;
Geiger, R ;
Noonan, J .
APPLIED SPECTROSCOPY REVIEWS, 1997, 32 (1-2) :45-101
[2]  
[Anonymous], ADV BIOCH ENG BIOTEC
[3]  
BRIMMER PJ, 1993, CAN J APPL SPECTROSC, V38, P155
[4]  
Chang R.K., 1982, Surface Enhanced Raman Scattering
[5]  
CRUEGER W, 1989, BIOTECHNOLOGY TXB IN
[6]  
Degen IA., 1997, TABLES CHARACTERISTI
[7]  
ERCKENS RJ, 1997, J TRAMA SPECTROSC, V28, P131
[8]   Rapid identification of urinary tract infection bacteria using hyperspectral whole-organism fingerprinting and artificial neural networks [J].
Goodacre, R ;
Timmins, ÉM ;
Burton, R ;
Kaderbhai, N ;
Woodward, AM ;
Kell, DB ;
Rooney, PJ .
MICROBIOLOGY-SGM, 1998, 144 :1157-1170
[9]   RAPID AND QUANTITATIVE-ANALYSIS OF METABOLITES IN FERMENTER BROTHS USING PYROLYSIS MASS-SPECTROMETRY WITH SUPERVISED LEARNING - APPLICATION TO THE SCREENING OF PENICILLIUM-CHRYSOGENUM FERMENTATIONS FOR THE OVERPRODUCTION OF PENICILLINS [J].
GOODACRE, R ;
TREW, S ;
WRIGLEYJONES, C ;
SAUNDERS, G ;
NEAL, MJ ;
PORTER, N ;
KELL, DB .
ANALYTICA CHIMICA ACTA, 1995, 313 (1-2) :25-43
[10]   Discrimination of bacteria using surface-enhanced Raman spectroscopy [J].
Jarvis, RM ;
Goodacre, R .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :40-47