Solid-state hydrogen sensor based on acid-doped polybenzimidazole

被引:22
作者
Bouchet, R [1 ]
Rosini, S [1 ]
Vitter, G [1 ]
Siebert, E [1 ]
机构
[1] ENSEEG, Lab Electrochim & Physicochim Mat & Interfaces, F-38402 St Martin Dheres, France
关键词
hydrogen sensor; potentiometric; Ag-AgCl reference electrode; solid electrolyte;
D O I
10.1016/S0925-4005(01)00655-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-state potentiometric hydrogen sensor for hydrogen determination in air is described. The device incorporates a protonic polymer electrolyte based on polybenzimidazole, an E-TEK gas diffusion electrode as sensing electrode and an Ag-AgCl electrode as reference electrode. The sensing mechanism of E-TEK can be explained by the mixed potential model. The stability of the reference system is demonstrated. The reference system is assumed to operate properly because of the existence of a thin hydrated layer containing chlorine ions. The sensor performances are reported. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:610 / 616
页数:7
相关论文
共 11 条
[1]   Use of NiO, anodically doped with Ni(III), as reference electrode for gas sensors based on proton conductors [J].
Alberti, G ;
Palombari, R ;
Pierri, F .
SOLID STATE IONICS, 1997, 97 (1-4) :359-364
[2]   Proton conduction in acid doped polybenzimidazole [J].
Bouchet, R ;
Siebert, E .
SOLID STATE IONICS, 1999, 118 (3-4) :287-299
[3]   Acid-doped polybenzimidazole as the membrane of electrochemical hydrogen sensors [J].
Bouchet, R ;
Siebert, E ;
Vitter, G .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (05) :L95-L97
[4]   Polybenzimidazole-based hydrogen sensors I. Mechanism of response with an E-TEK gas diffusion electrode [J].
Bouchet, R ;
Siebert, E ;
Vitter, G .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (08) :3125-3130
[5]   AN NMR-STUDY OF ABSORBED WATER IN POLYBENZIMIDAZOLE [J].
BROOKS, NW ;
DUCKETT, RA ;
ROSE, J ;
WARD, IM ;
CLEMENTS, J .
POLYMER, 1993, 34 (19) :4038-4042
[6]   Synthesis and proton conductivity of thermally stable polymer electrolyte: poly(benzimidazole) complexes with strong acid molecules [J].
Kawahara, M ;
Morita, J ;
Rikukawa, M ;
Sanui, K ;
Ogata, N .
ELECTROCHIMICA ACTA, 2000, 45 (8-9) :1395-1398
[7]   SENSING CHARACTERISTICS AND WORKING MECHANISM OF 4-PROBE TYPE SOLID-STATE HYDROGEN SENSOR USING PROTON CONDUCTOR [J].
MIURA, N ;
HARADA, T ;
YAMAZOE, N .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (04) :1215-1219
[8]  
MIURA N, 1992, CHEM SOLID STATE MAT, V2, P527
[9]   Electrochemical sensors with solid polymer electrolytes [J].
Opekar, F ;
Stulík, K .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :151-162
[10]   Hydrogen sensor based on antimonium pentoxide phosphoric acid solid electrolyte [J].
Ponomareva, VG ;
Lavrova, GV ;
Hairetdinov, EF .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) :95-98