Beta2-microglobulin removal by extracorporeal renal replacement therapies

被引:15
作者
Krieter, DH
Lemke, HD
Canaud, B
Wanner, C
机构
[1] Univ Wurzburg, Div Nephrol, Dept Med, D-97080 Wurzburg, Germany
[2] Univ Montpellier, Lapeyronie Hosp, Dept Nephrol, F-34059 Montpellier, France
[3] Membrana Res, Obernburg, Germany
来源
BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS | 2005年 / 1753卷 / 01期
关键词
beta(2)-microglobulin; beta(2)-microglobulin removal; clinical haemodialysis; haemofiltration; haemodiafiltration;
D O I
10.1016/j.bbapap.2005.08.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There is increasing evidence that end-stage renal disease patients with lower beta(2)-microglobulin plasma levels and patients on convective renal replacement therapy are at lower mortality risk. Therefore, an enhanced beta2-microglobulin removal by renal replacement procedures has to be regarded as a contribution to a more adequate dialysis therapy. In contrast to high-flux dialysis, low-flux hemodialysis is not qualified to eliminate substantial amounts of beta(2)-microglobulin. In hemodialysis using modem high-flux dialysis membranes, a beta(2)-microglobulin removal similar to that obtained in hemofiltration or hemodiafiltration can be achieved. Several of these high-flux membranes are protein-leaking, making them suitable only for hemodialysis due to a high albumin loss when used in more convective therapy procedures. On-line hemodiafiltration infusing large substitution fluid volumes represents the most efficient and innovative renal replacement therapy form. To maximize beta(2)-microglobulin removal, modifications of this procedure have been proposed. These modifications ensure safer operating conditions, such as mixed hemodiafiltration, or control albumin loss at maximum purification from beta(2)-microglobulin, such as mid-dilution hemodiafiltration, push/pull hemodiafiltration or programmed filtration. Whether these innovative hemodiafiltration options will become accepted in clinical routine use needs to be proven in future. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 67 条
[51]   On-line mixed hemodiafiltration with a feedback for ultrafiltration control: Effect on middle-molecule removal [J].
Pedrini, LA ;
de Cristofaro, V .
KIDNEY INTERNATIONAL, 2003, 64 (04) :1505-1513
[52]   Convective-control led double high flux hemodiafiltration: A novel blood purification modality [J].
Pisitkun, T ;
Eiam-Ong, S ;
Tiranathanagul, K ;
Sakunsrijinda, C ;
Manotham, K ;
Hanvivatvong, O ;
Suntaranuson, P ;
Praditpornsilpa, K ;
Chusil, S ;
Tungsanga, K .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2004, 27 (03) :195-204
[53]   Filtration of native and glycated β2-microglobulin by charged and neutral dialysis membranes [J].
Randoux, C ;
Gillery, P ;
Georges, N ;
Lavaud, S ;
Chanard, J .
KIDNEY INTERNATIONAL, 2001, 60 (04) :1571-1577
[54]   Effects of a reduced inner diameter of hollow fibers in hemodialyzers [J].
Ronco, C ;
Brendolan, A ;
Lupi, A ;
Metry, G ;
Levin, NW .
KIDNEY INTERNATIONAL, 2000, 58 (02) :809-817
[55]   First clinical experience with an adjunctive hemoperfusion device designed specifically to remove β2-microglobulin in hemodialysis [J].
Ronco, C ;
Brendolan, A ;
Winchester, JF ;
Golds, E ;
Clemmer, J ;
Polaschegg, HD ;
Muller, TE ;
La Greca, G ;
Levin, NW .
BLOOD PURIFICATION, 2001, 19 (02) :260-263
[56]   Beta 2-microglobulin removal by synthetic dialysis membranes. Mechanisms and kinetics of the molecule [J].
Ronco, C ;
Heifetz, A ;
Fox, K ;
Curtin, C ;
Brendolan, A ;
Gastaldon, F ;
Crepaldi, C ;
Fortunato, A ;
Pietribasi, G ;
Caberlotto, A ;
Brunello, A ;
Manani, SM ;
Zanella, M ;
LaGreca, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (03) :136-143
[57]   Comparison of the new polyethersulfone high-flux membrane DIAPES® HF800 with conventional high-flux membranes during on-line haemodiafiltration [J].
Samtleben, W ;
Dengler, C ;
Reinhardt, B ;
Nothdurft, A ;
Lemke, HD .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (11) :2382-2386
[58]  
SHALDON S, 1981, T AM SOC ART INT ORG, V27, P610
[59]   Alternate repetition of short fore- and backfiltrations reduces convective albumin loss [J].
Shinzato, T ;
Miwa, M ;
Nakai, S ;
Takai, I ;
Matsumoto, Y ;
Morita, H ;
Miyata, T ;
Maeda, K .
KIDNEY INTERNATIONAL, 1996, 50 (02) :432-435
[60]   Validation of a two-pool model for the kinetics of β2-microglobulin [J].
Stiller, S ;
Xu, XQ ;
Gruner, N ;
Vienken, J ;
Mann, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (05) :411-420