Hemodynamic effects of intrathecal fentanyl in nonlaboring term parturients

被引:21
作者
Grant, GJ
Susser, L
Cascio, M
Moses, M
Zakowski, MI
机构
[1] Department of Anesthesiology, New York University Medical Center, New York, NY
[2] Department of Anesthesiology, New York University Medical Center, New York, NY 10016
关键词
fentanyl; intrathecal hemodynamics; pregnancy;
D O I
10.1016/0952-8180(95)00174-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To determine the effect of intrathecal fentanyl on maternal hemodynamics. Design: Prospective. Setting: Labor and delivery suite of a university medical center. Patients: 23 ASA status I nonlaboring term parturients presenting for elective cesarean section. Interventions: Patients were given either 1,200 ml lactated Ringer's Solution (Group 1, n = 12) or no intravenous (IV) fluid (Group 2, n = 11). A combined spinal-epidural technique was then performed. Fentanyl 25 mu g was administered intrathecally through a 24-gauge Sprotte or 25-gauge Whitacre spinal needle. After completion of the hemodynamic study, a catheter was threaded into the epidural space for local anesthetic administration. Measurements and Main Results: Baseline hemodynamic data [systolic (SBP), diastolic, and mean arterial pressure, heart rate, stroke volume, cardiac output, end-diastolic volume, and ejection fraction] were obtained in triplicate using noninvasive blood pressure monitoring and impedance cardiography After administration of intrathecal fentanyl, , hemodynamic measurements were recorded at 3-minute intervals for 30 minutes. These values were compared with baseline for both groups. Ten patients in each group completed the study. Intrathecal fentanyl administration did not result in any maternal hemodynamic changes in Group 1, and a few small statistically significant changes in Group 2. Measured SBP was always greater than 100 mmHg in all patients during the study. Conclusion: Intrathecal administration of fentanyl 25 mu g in nonlaboring term parturients does not produce clinically maternal hemodynamic changes.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 21 条
[11]  
LEIGHTON BL, 1989, ANESTH ANALG, V69, P122
[12]  
MANDELL G, 1994, ANESTHESIOLOGY, V81, pA1152
[13]   RELIABILITY OF IMPEDANCE CARDIOGRAPHY IN MEASURING CENTRAL HEMODYNAMICS [J].
MEHLSEN, J ;
BONDE, J ;
STADEAGER, C ;
REHLING, M ;
TANGO, M ;
TRAPJENSEN, J .
CLINICAL PHYSIOLOGY, 1991, 11 (06) :579-588
[14]  
NEWMAN LM, 1994, ANESTHESIOLOGY, V81, pA1153
[15]  
Perrino A C Jr, 1994, J Cardiothorac Vasc Anesth, V8, P24, DOI 10.1016/1053-0770(94)90007-8
[16]  
RILEY ET, 1994, ANESTHESIOLOGY, V81, pA1146
[17]  
STEIN SA, 1994, ANESTHESIOLOGY, V81, pA1143
[18]  
UELAND K, 1969, AM J OBSTET GYNECOL, V103, P1
[19]   REPRODUCIBILITY OF HEMODYNAMIC MEASUREMENTS BY IMPEDANCE CARDIOGRAPHY [J].
VEIGL, VL ;
JUDY, WV .
CARDIOVASCULAR RESEARCH, 1983, 17 (12) :728-734
[20]  
YAKSH TL, 1977, J PHARMACOL EXP THER, V202, P411