Capillary electrophoresis of trace metals in highly saline physiological sample matrices

被引:32
作者
Riaz, A [1 ]
Kim, B [1 ]
Chung, DS [1 ]
机构
[1] Seoul Natl Univ, Sch Chem, Seoul 151747, South Korea
关键词
capillary electrophoresis; trace metals; transient isotachophoresis; urine;
D O I
10.1002/elps.200305537
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Trace metal ions in highly saline samples such as urine were determined with capillary electrophoresis (CE) without desalting or off-line preconcentration. By mixing with a dye, 4-(2-pyridylazo) resorcinol (PAR), the metal ions were converted into anionic complexes having strong absorbance near 500 nm. A large volume of the metal-PAR complex sample solution injected into a coated capillary was stacked isotachophoretically and separated under a reverse potential. The salt anion (chloride) and PAR in the sample matrix acted as the leading and terminating electrolytes, respectively. In a sample containing a 250 mm NaCl matrix, more than 400-fold enhancement in the absorbance detector response was realized compared to the normal CE injection mode. Combination of the dye complexation and isotachophoretic stacking provided excellent detection limits (S/N = 3) for three trace metal ions in the low ppb range (Fe2+, 0.7 ppb, Ni2+, 0.4 ppb; Zn2+, 1.2 ppb) with absorbance detection. The migration time reproducibility was excellent (relative standard deviations: standard samples < 1%, urine samples similar to 1%). The proposed method is convenient and fast, and the sample analysis can be completed within 20 min.
引用
收藏
页码:2788 / 2795
页数:8
相关论文
共 55 条
[1]  
Baker D. R., 1995, CAPILLARY ELECTROPHO
[2]   Zinc deficiency and child development [J].
Black, MM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 68 (02) :464S-469S
[3]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[4]   Investigation of matrix effects in capillary zone electrophoresis [J].
Boden, J ;
Bachmann, K .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :319-330
[5]   Selective focusing of catecholamines and weakly acidic compounds by capillary electrophoresis using a dynamic pH junction [J].
Britz-McKibbin, P ;
Chen, DDY .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1242-1252
[6]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[7]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[8]   Transient isotachophoretic-electrophoretic separations of lanthanides with indirect laser-induced fluorescence detection [J].
Church, MN ;
Spear, JD ;
Russo, RE ;
Klunder, GL ;
Grant, PM ;
Andresen, BD .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2475-2480
[9]   Capillary electrophoresis of anions at high salt concentrations [J].
Ding, WL ;
Thornton, MJ ;
Fritz, JS .
ELECTROPHORESIS, 1998, 19 (12) :2133-2139
[10]   TRACE ANALYSIS OF PROTEINS BY CAPILLARY ZONE ELECTROPHORESIS WITH ON-COLUMN TRANSIENT ISOTACHOPHORETIC PRECONCENTRATION [J].
FORET, F ;
SZOKO, E ;
KARGER, BL .
ELECTROPHORESIS, 1993, 14 (5-6) :417-428