Determination of parabens in pharmaceutical formulations by solid-phase microextraction-ion mobility spectrometry

被引:83
作者
Lokhnauth, JK [1 ]
Snow, NH [1 ]
机构
[1] Seton Hall Univ, Dept Chem & Biochem, S Orange, NJ 07079 USA
关键词
D O I
10.1021/ac0504013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) coupled with ion mobility spectrometry (IMS) was used for the detection and quantitation of 4-hydroxybenzoate preservatives, methylparaben, ethylparaben, propylparaben, and butylparaben, in commercial pharmaceutical products. For the first time, SPME-IMS is described for the simultaneous detection, separation, and quantitation of multiple analytes in complex matrixes. The parabens are extracted from the samples using SPME, and the analytes on the fiber are heated by the IMS desorber unit and vaporized into the drift tube. The four preservatives differing only by a methyl group were separated in less than 18 ms. The analytical procedure was optimized for fiber coating selection, extraction time, sample pH, sample volume, ionic strength, and IMS conditions. Separation characteristics such as resolution, theoretical plates, and drift times of the parabens were also evaluated based on the direct interfacing of SPME to IMS. The conditions were tested using six over-the-counter topical products containing various combinations of preservatives. Analysis of the samples by SPME-IMS using benzyl paraben as an internal standard yields good comparison to an HPLC method, thereby reinforcing the applicability of this technique as a method for routine analysis. Limits of detection were 10 ng/mL for methylparaben and ethylparaben and 5 ng/mL for propylparaben and butylparaben. Good linearity range and reproducibility of less than 8% were obtained.
引用
收藏
页码:5938 / 5946
页数:9
相关论文
共 33 条
[1]   High performance liquid chromatographic determination of phenoxetol, methyl paraben, ethyl paraben, n-propyl paraben, iso-butyl paraben, n-butyl paraben and croconazole center dot HCl [J].
Akhtar, MJ ;
Khan, S ;
Roy, IM ;
Jafri, IA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (11) :1609-1613
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]  
Asbury GR, 2000, J MICROCOLUMN SEP, V12, P172, DOI 10.1002/(SICI)1520-667X(2000)12:3<172::AID-MCS7>3.0.CO
[4]  
2-W
[5]   Validation of a micellar electrokinetic capillary chromatography method for the determination of imidurea, methyl and propylparabens in a pharmaceutical ointment [J].
Baalbaki, B ;
Blanchin, MD ;
Fabre, H .
ANALYTICA CHIMICA ACTA, 2002, 463 (01) :15-20
[6]   MASS-MOBILITY CORRELATION OF IONS IN VIEW OF NEW MOBILITY DATA [J].
BERANT, Z ;
KARPAS, Z .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (11) :3819-3824
[7]   PRE-COLUMN REACTIONS TO ELIMINATE INTERFERENTS IN LIQUID-CHROMATOGRAPHIC ANALYSIS OF PARA-HYDROXYBENZOATES IN COMPLEX PHARMACEUTICALS [J].
CANTWELL, FF .
ANALYTICAL CHEMISTRY, 1976, 48 (13) :1854-1859
[8]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[9]   Improved analysis of MTBE, TAME, and TBA in petroleum fuel-contaminated groundwater by SPME using deuterated internal standards with GC-MS [J].
Dewsbury, P ;
Thornton, SF ;
Lerner, DN .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (07) :1392-1397
[10]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO