Determination of parabens in pharmaceutical formulations by solid-phase microextraction-ion mobility spectrometry

被引:83
作者
Lokhnauth, JK [1 ]
Snow, NH [1 ]
机构
[1] Seton Hall Univ, Dept Chem & Biochem, S Orange, NJ 07079 USA
关键词
D O I
10.1021/ac0504013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) coupled with ion mobility spectrometry (IMS) was used for the detection and quantitation of 4-hydroxybenzoate preservatives, methylparaben, ethylparaben, propylparaben, and butylparaben, in commercial pharmaceutical products. For the first time, SPME-IMS is described for the simultaneous detection, separation, and quantitation of multiple analytes in complex matrixes. The parabens are extracted from the samples using SPME, and the analytes on the fiber are heated by the IMS desorber unit and vaporized into the drift tube. The four preservatives differing only by a methyl group were separated in less than 18 ms. The analytical procedure was optimized for fiber coating selection, extraction time, sample pH, sample volume, ionic strength, and IMS conditions. Separation characteristics such as resolution, theoretical plates, and drift times of the parabens were also evaluated based on the direct interfacing of SPME to IMS. The conditions were tested using six over-the-counter topical products containing various combinations of preservatives. Analysis of the samples by SPME-IMS using benzyl paraben as an internal standard yields good comparison to an HPLC method, thereby reinforcing the applicability of this technique as a method for routine analysis. Limits of detection were 10 ng/mL for methylparaben and ethylparaben and 5 ng/mL for propylparaben and butylparaben. Good linearity range and reproducibility of less than 8% were obtained.
引用
收藏
页码:5938 / 5946
页数:9
相关论文
共 33 条
[21]  
Okeyo PD, 1998, J MICROCOLUMN SEP, V10, P551, DOI 10.1002/(SICI)1520-667X(1998)10:7<551::AID-MCS1>3.3.CO
[22]  
2-O
[23]   Evaluation of solid phase microextraction in detection of contraband drug vapors [J].
Orzechowska, GE ;
Poziomek, EJ ;
Tersol, V ;
Homstead, J .
CHEMISTRY- AND BIOLOGY-BASED TECHNOLOGIES FOR CONTRABAND DETECTION, 1997, 2937 :8-18
[24]  
Orzechowska GE, 1997, ANAL LETT, V30, P1437
[25]   Determination of amphetamines in human urine by headspace solid-phase microextraction and gas chromatography [J].
Raikos, N ;
Christopoulou, K ;
Theodoridis, G ;
Tsoukali, H ;
Psaroulis, D .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (01) :59-63
[26]   Some alkyl hydroxy benzoate preservatives (parabens) are estrogenic [J].
Routledge, EJ ;
Parker, J ;
Odum, J ;
Ashby, J ;
Sumpter, JP .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1998, 153 (01) :12-19
[27]   Simultaneous HPLC determination of multiple components in a commercial cosmetic cream [J].
Sotofattori, E ;
Anzaldi, M ;
Balbi, A ;
Tonello, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) :213-217
[28]   Comparison of quantitative high performance thin layer chromatography and the high performance liquid chromatography of parabens [J].
Thomassin, M ;
Cavalli, E ;
Guillaume, Y ;
Guinchard, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (06) :831-838
[29]   Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry [J].
Tong, H ;
Sze, N ;
Thomson, B ;
Nacson, S ;
Pawliszyn, J .
ANALYST, 2002, 127 (09) :1207-1210
[30]   Determination of parabens in cosmetic products by supercritical fluid extraction and capillary zone electrophoresis [J].
Wang, SP ;
Chang, CL .
ANALYTICA CHIMICA ACTA, 1998, 377 (01) :85-93