Determination of nicotine and its metabolites in urine by solid-phase extraction and sample stacking capillary electrophoresis-mass spectrometry

被引:54
作者
Baidoo, EEK [1 ]
Clench, MR [1 ]
Smith, RF [1 ]
Tetler, LW [1 ]
机构
[1] Sheffield Hallam Univ, Ctr Biomed Res, Sheffield S1 1WB, S Yorkshire, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 796卷 / 02期
关键词
sample stacking; nicotine; metabolites;
D O I
10.1016/j.jchromb.2003.08.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combination of capillary electrophoresis (CE) and mass spectrometry (MS) with solid-phase extraction (SPE) has been used for the identification of nicotine and eight of its metabolites in urine. The recovery of cotinine from cotinine-spiked urine, by C18 SPE, was found to be 98%. Smokers urine (200 ml) was preconcentrated 200-fold via SPE prior to analysis. The sample stacking mode of CE, when compared to capillary zone electrophoresis, was shown to improve peak efficiency by 132-fold. The combination of hydrodynamic and electrokinetic injection was studied with sample stacking/CE/MS. The on-column limits of detection (LOD) of nicotine and cotinine, by this technique, were found to be 0.11 and 2.25 mug/ml, respectively. Hence, LODs of nicotine and cotinine in urine after 200-fold preconcentration were 0.55 and 11.25 ng/ml, respectively. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 23 条
[1]   A solid phase extraction method for determination of nicotine in serum and urine by isotope dilution gas chromatography mass spectrometry with selected ion monitoring [J].
Baskin, LB ;
Anderson, RW ;
Charlson, JR ;
Hurt, RD ;
Lawson, GM .
ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 :522-527
[2]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2747, DOI 10.1002/1522-2683(20000801)21:14<2747::AID-ELPS2747>3.0.CO
[3]  
2-Z
[4]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[5]  
Chambers KL, 2001, BRIT J BIOMED SCI, V58, P61
[6]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[7]   ELECTROOSMOTIC PROPERTIES AND PEAK BROADENING IN FIELD-AMPLIFIED CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
HELMER, JC .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1354-1361
[8]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[9]   FIELD-AMPLIFIED POLARITY-SWITCHING SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :153-161
[10]   MORTALITY IN RELATION TO SMOKING - 40 YEARS OBSERVATIONS ON MALE BRITISH DOCTORS [J].
DOLL, R ;
PETO, R ;
WHEATLEY, K ;
GRAY, R ;
SUTHERLAND, I .
BRITISH MEDICAL JOURNAL, 1994, 309 (6959) :901-911