Dynamic arraying of microbeads for bioassays in microfluidic channels

被引:53
作者
Lilliehorn, T [1 ]
Nilsson, M
Simu, U
Johansson, S
Almqvist, M
Nilsson, J
Laurell, T
机构
[1] Uppsala Univ, Dept Engn Sci, Uppsala, Sweden
[2] Lund Inst Technol, Dept Elect Measurement Technol, Lund, Sweden
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 106卷 / 02期
关键词
ultrasound; microchannel; trapping; bead; array; proteomics;
D O I
10.1016/j.snb.2004.07.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposes a new dynamic mode of generating bioanalytical arrays in microfluidic systems, based on ultrasonic trapping of microbeads using acoustic forces in standing waves. Trapping of microbead clusters in an array format within a flow-through device is demonstrated for the first time using a device with three integrated ultrasonic microtransducers. The lateral extension of each trapping site was essentially determined by the corresponding microtransducer dimensions, 0.8 mm x 0.8 mm. The flow-through volume was approximately 1 mu l and the trapping site volumes about 100 nl each. The strength of trapping was investigated, showing that 50% of the initially trapped beads were still trapped at a perfusion rate of 10 mu l/min. A fluorescence based avidin bioassay was successfully performed on biotin-coated microbeads trapped in the flow-through device, providing a first proof of principle of the proposed dynamic arraying concept. The dynamic arraying is believed to be expandable to two dimensions, thus, with a prospect of performing targeted and highly parallel protein analysis in microfluidic devices. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:851 / 858
页数:8
相关论文
共 24 条
[1]   Protein arrays: The current state-of-the-art [J].
Cutler, P .
PROTEOMICS, 2003, 3 (01) :3-18
[2]   Clinical biomarkers in drug discovery and development [J].
Frank, R ;
Hargreaves, R .
NATURE REVIEWS DRUG DISCOVERY, 2003, 2 (07) :566-580
[3]   UPPER SOUND PRESSURE LIMITS ON PARTICLE CONCENTRATION IN FIELDS OF ULTRASONIC STANDING-WAVE AT MEGAHERTZ FREQUENCIES [J].
GOULD, RK ;
COAKLEY, WT ;
GRUNDY, MA .
ULTRASONICS, 1992, 30 (04) :239-244
[4]  
Groschl H, 1998, ACUSTICA, V84, P815
[5]   Single half-wavelength ultrasonic particle filter:: Predictions of the transfer matrix multilayer resonator model and experimental filtration results [J].
Hawkes, JJ ;
Coakley, WT ;
Gröschl, M ;
Benes, E ;
Armstrong, S ;
Tasker, PJ ;
Nowotny, H .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 111 (03) :1259-1266
[6]   DNA microarray technology: Devices, systems, and applications [J].
Heller, MJ .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 :129-153
[7]   Multilayer telescopic piezoactuator fabricated by a prototyping process based on milling [J].
Lilliehorn, T ;
Simu, U ;
Johansson, S .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 107 (02) :159-168
[8]  
LILLIEHORN T, IN PRESS ULTRASONICS
[9]  
MacBeath G, 2000, SCIENCE, V289, P1760
[10]   Fingerprinting the circulating repertoire of antibodies from cancer patients [J].
Mintz, PJ ;
Kim, J ;
Do, KA ;
Wang, XM ;
Zinner, RG ;
Cristofanilli, M ;
Arap, MA ;
Hong, WK ;
Troncoso, P ;
Logothetis, CJ ;
Pasqualini, R ;
Arap, W .
NATURE BIOTECHNOLOGY, 2003, 21 (01) :57-63