Characteristics of a commercially available film digitizer and their significance for film dosimetry

被引:48
作者
Mersseman, B [1 ]
De Wagter, C [1 ]
机构
[1] Univ Hosp Gent, Dept Radiotherapy & Nucl Med, B-9000 Ghent, Belgium
关键词
D O I
10.1088/0031-9155/43/6/030
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dosimetric detectors used in high-energy photon radiation dosimetry mainly perform a zero-or one-dimensional measurement. These low-dimensional methods are not always adequate in the context of conformal radiotherapy. Therefore, two-dimensional film dosimetry has attracted attention. We studied a 12-bit CCD-based film digitizer (Vidar VXR-12) with regard to accurate film dosimetry. We investigated the stability, linearity, noise, effects of aberrant light scatter and built-in conversion tables. A digitizing resolution of 75 dpi and a digitizing speed of 20 ms/line result in an optimal signal-to-noise ratio. At optical densities above 2.0, the reading accuracy of the digitizer is limited by noise. The results of various experiments prove both the capabilities and limitations of the digitizer studied. We also propose a method to acquire and process film data using such a digitizer.
引用
收藏
页码:1803 / 1812
页数:10
相关论文
共 11 条
[1]   A convolution model to convert transmission dose images to exit dose distributions [J].
Boellaard, R ;
vanHerk, M ;
Mijnheer, BJ .
MEDICAL PHYSICS, 1997, 24 (02) :189-199
[2]  
BRIOT E, 1995, P 11 ANN S BELG HOSP, P18
[3]   SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[4]  
DEDEENE Y, 1996, P INT SOC MAGN RES M, P1593
[5]   INVESTIGATION OF THE IMAGING PROPERTIES OF AN X-RAY-FILM SCANNER [J].
DOLER, W ;
RASSOW, S ;
JAGER, A ;
VOSSHENRICH, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (05) :917-922
[6]  
HUYSKENS D, 1996, 4 INT WORKSH EL PORT, P43
[7]   Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters [J].
Ibbott, GS ;
Maryanski, MJ ;
Eastman, P ;
Holcomb, SD ;
Zhang, YS ;
Avison, RG ;
Sanders, M ;
Gore, JC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05) :1097-1103
[8]   Dosimeter gel and MR imaging for verification of calculated dose distributions in clinical radiation therapy [J].
Johansson, SA ;
Magnusson, P ;
Fransson, A ;
Olsson, LE ;
Christoffersson, JO ;
Montelius, A ;
Mattsson, S .
ACTA ONCOLOGICA, 1997, 36 (03) :283-290
[9]   TESTS FOR EVALUATING LASER FILM DIGITIZERS [J].
MEEDER, RJJ ;
JAFFRAY, DA ;
MUNRO, P .
MEDICAL PHYSICS, 1995, 22 (05) :635-642
[10]   FILM DOSIMETRY OF CLINICAL ELECTRON-BEAMS [J].
VANBATTUM, LJ ;
HUIZENGA, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :69-76