Dosimeter gel and MR imaging for verification of calculated dose distributions in clinical radiation therapy

被引:24
作者
Johansson, SA
Magnusson, P
Fransson, A
Olsson, LE
Christoffersson, JO
Montelius, A
Mattsson, S
机构
[1] UNIV UPPSALA HOSP,DEPT HOSP PHYS,UPPSALA,SWEDEN
[2] UNIV VIENNA,DEPT BIOMED ENGN & PHYS,VIENNA,AUSTRIA
关键词
D O I
10.3109/02841869709001264
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A dosimeter gel, based on an agarose gel infused with a ferrous sulphate solution and evaluated in a magnetic resonance scanner, was used for complete Verification of calculated dose distributions. Two standard treatment procedures, treatment of cancer in the urinary bladder and treatment of breast cancer after modified radical mastectomy, were examined using pixel-by-pixel and dose volume histogram comparison. The dose distributions calculated with the dose planning system was in very good agreement with the measured ones. However, in the case of the more complicated breast cancer treatment, some discrepancies were found, mainly at the beam abutment region. This may be explained by held displacements errors and by a small limitation of the dose planning utilising small electron beams in this region. The dosimeter gel system have proven to be a useful tool for dosimetry in clinical radiation therapy applications.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 1993, 50 ICRU
[2]   IMAGING OF SPATIAL RADIATION-DOSE DISTRIBUTION IN AGAROSE GELS USING MAGNETIC-RESONANCE [J].
APPLEBY, A ;
CHRISTMAN, EA ;
LEGHROUZ, A .
MEDICAL PHYSICS, 1987, 14 (03) :382-384
[3]   Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning [J].
Blomquist, M ;
Karlsson, M ;
Karlsson, M .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (03) :271-286
[4]  
Brahme A, 1988, ACTA ONCOL S, V1, P5
[5]   CONFIRMATION OF TARGET LOCALIZATION AND DOSIMETRY FOR 3D CONFORMAL RADIOTHERAPY TREATMENT PLANNING BY MR-IMAGING OF A FERROUS SULFATE GEL HEAD PHANTOM [J].
CHAN, MF ;
AYYANGAR, KM .
MEDICAL PHYSICS, 1995, 22 (07) :1171-1175
[7]   Anthropomorphic phantom measurements for the validation of a treatment planning system [J].
Dunscombe, P ;
McGhee, P ;
Lederer, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) :399-411
[8]   MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING [J].
GORE, JC ;
KANG, YS ;
SCHULZ, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1189-1197
[9]   ABUTMENT OF HIGH-ENERGY ELECTRON FIELDS [J].
HARMS, WB ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (04) :853-858
[10]  
HELMIUS E, 1993, THESIS STOCKHOLM U