Anthropomorphic phantom measurements for the validation of a treatment planning system

被引:16
作者
Dunscombe, P
McGhee, P
Lederer, E
机构
[1] LAURENTIAN UNIV,DEPT PHYS,SUDBURY,ON P3E 2C6,CANADA
[2] UNIV OTTAWA,FAC MED,OTTAWA,ON K1H 8L6,CANADA
关键词
D O I
10.1088/0031-9155/41/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A series of eight irradiations of an anthropomorphic phantom has been performed as part of a programme of treatment planning system (TPS) validation. The 'treatment' configurations used represent a realistic cross section of those carried our routinely in a radiotherapy centre. The dose distributions within the phantom were determined using 75 LiF TLD chips per irradiation and the measured dose distributions were compared with calculations performed on a TPS for three ranges of dose gradient. The accuracy of the technique per measurement point is estimated to be 3% in dose (low dose gradient) and 3 mm in position (high dose gradient). The measurement and data analysis techniques used permit evaluation of a TPS against recently recommended criteria of acceptability although it is noted that is is nor possible to isolate TPS performance from factors depending on, for example, open beam data fitting and treatment set up accuracy.
引用
收藏
页码:399 / 411
页数:13
相关论文
共 15 条
[1]  
BRAHME A, 1988, ACTA ONCOL S, V1, P32
[2]  
Cygler J, 1988, Med Dosim, V13, P155
[3]   THE DOSIMETRIC VERIFICATION OF A PENCIL BEAM BASED TREATMENT PLANNING SYSTEM [J].
KNOOS, T ;
CEBERG, C ;
WEBER, L ;
NILSSON, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1609-1628
[4]   CHANGES IN THE DOSE-PROFILE OF A 10-MV X-RAY-BEAM WITHIN AND BEYOND LOW-DENSITY MATERIAL [J].
KORNELSEN, RO ;
YOUNG, MEJ .
MEDICAL PHYSICS, 1982, 9 (01) :114-116
[5]   INTERCOMPARISON OF RADIOTHERAPY TREATMENT PLANNING SYSTEMS FOR EXTERNAL PHOTON AND ELECTRON-BEAM DOSE CALCULATIONS [J].
KOSUNEN, A ;
JARVINEN, H ;
VATNITSKIJ, S ;
ERMAKOV, I ;
CHERVJAKOV, A ;
KULMALA, J ;
PITKANEN, M ;
VAYRYNEN, T ;
VAANANEN, A .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :327-335
[6]  
KUTCHER GJ, 1994, MED PHYS, V21, P582
[7]   PERFORMANCE EVALUATION OF COMPUTERIZED TREATMENT PLANNING SYSTEMS FOR RADIOTHERAPY - EXTERNAL PHOTON BEAMS [J].
MCCULLOUGH, EC ;
KRUEGER, AM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (11) :1599-1605
[8]   ACCEPTANCE TESTING COMPUTERIZED RADIATION-THERAPY TREATMENT PLANNING SYSTEMS - DIRECT UTILIZATION OF CT SCAN DATA [J].
MCCULLOUGH, EC ;
HOLMES, TW .
MEDICAL PHYSICS, 1985, 12 (02) :237-242
[9]  
McGhee P, 1993, Med Dosim, V18, P187
[10]  
Meyer SL., 1975, Data analysis for scientists and engineers