Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

被引:80
作者
Kerckhofs, G. [1 ]
Schrooten, J. [1 ]
Van Cleynenbreugel, T. [2 ,3 ]
Lomov, S. V. [1 ]
Wevers, M. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Met & Mat Engn, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Div Biomech & Engn Design, B-3001 Louvain, Belgium
[3] Technologielaan, B-3001 Louvain, Belgium
关键词
D O I
10.1063/1.2838584
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found. (c) 2008 American Institute of Physics.
引用
收藏
页数:9
相关论文
共 43 条
[1]
Analysis of pore interconnectivity in bioactive glass foams using X-ray microtomography [J].
Atwood, RC ;
Jones, JR ;
Lee, PD ;
Hench, LL .
SCRIPTA MATERIALIA, 2004, 51 (11) :1029-1033
[2]
Mechanical analysis and microstructural characterisation of metal foams [J].
Benouali, AH ;
Froyen, L ;
Delerue, JF ;
Wevers, M .
MATERIALS SCIENCE AND TECHNOLOGY, 2002, 18 (05) :489-494
[3]
Comparison insight bone measurements by histomorphometry and μCT [J].
Chappard, D ;
Retailleau-Gaborit, N ;
Legrand, E ;
Baslé, MF ;
Audran, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (07) :1177-1184
[4]
Recent progress in X-ray CT as a geosciences tool [J].
Cnudde, V. ;
Masschaele, B. ;
Dierick, M. ;
Vlassenbroeck, J. ;
Van Hoorebeke, L. ;
Jacobs, P. .
APPLIED GEOCHEMISTRY, 2006, 21 (05) :826-832
[5]
Artefacts in X-ray microtomography of materials [J].
Davis, G. R. ;
Elliott, J. C. .
MATERIALS SCIENCE AND TECHNOLOGY, 2006, 22 (09) :1011-1018
[6]
De Man B, 1999, IEEE T NUCL SCI, V46, P691, DOI 10.1109/23.775600
[7]
Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :977-981
[8]
Age variations in the properties of human tibial trabecular bone [J].
Ding, M ;
Dalstra, M ;
Danielsen, CC ;
Kabel, J ;
Hvid, I ;
Linde, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :995-1002
[9]
Accuracy of cancellous bone volume fraction measured by micro-CT scanning [J].
Ding, M ;
Odgaard, A ;
Hvid, I .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :323-326
[10]
Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections [J].
Fajardo, RJ ;
Ryan, TM ;
Kappelman, J .
AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, 118 (01) :1-10