Reversed-phase electrochromatography with a monolithic microcolumn prepared in a 2.2-mm-inner diameter fused-silica tube

被引:17
作者
Deng, N [1 ]
He, YZ [1 ]
Wang, L [1 ]
Wang, XK [1 ]
Su, QD [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
D O I
10.1021/ac050589q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrochromatography possesses advantages of high separation efficiency and velocity, but it also has its disadvantages due to its small inner diameter, such as poor detection sensitivity, low sample capacity, and some trouble in its column preparation. To overcome these shortcomings, a monolithic microcolumn with a surface area larger than 200 m(2)/g was prepared by sol-gel polycondensation of tetraethoxysilane-hydrochlotic acid-poly(ethylene glycol) and filling with fine quartz sand in a 2.2-mm-i.d. fused-silica tube. The prepared microcolumn was used in the separation of aromatic compounds by reversed-phase electrochromatography. Some factors that affected electroosmotic flow were explored, such as electric field strength, buffer concentration, and buffer pH. Acetonitrile concentration in the mobile phase was investigated for phenol, benzene, and naphthalene separation. The separation results were satisfying with the electrochromatographic microcolumns. The detection limits of phenol, benzene, and naphthalene were 0.07, 0.26, and 0.04 mg/L, respectively.
引用
收藏
页码:5622 / 5627
页数:6
相关论文
共 18 条
[1]   Semipreparative capillary electrochromatography [J].
Chen, JR ;
Zare, RN ;
Peters, EC ;
Svec, F ;
Frechét, JJ .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :1987-1992
[2]   Capillary electrochromatography - A high-efficiency micro-separation technique [J].
Dittmann, MM ;
Rozing, GP .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :63-74
[3]   A STATIONARY-PHASE FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY AND ELECTROCHROMATOGRAPHY USING SOL-GEL TECHNOLOGY [J].
GUO, Y ;
COLON, LA .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2511-2516
[4]  
HE YZ, 2005, Patent No. 2005100386775
[5]   Performance of a monolithic silica column in a capillary under pressure-driven and electrodriven conditions [J].
Ishizuka, N ;
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Nagayama, H ;
Hosoya, K ;
Tanaka, N .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1275-1280
[6]   HIGH-RESOLUTION SEPARATIONS BASED ON ELECTROPHORESIS AND ELECTROOSMOSIS [J].
JORGENSON, JW ;
LUKACS, KD .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :209-216
[7]   MINIATURIZATION IN PRESSURE AND ELECTROENDOSMOTICALLY DRIVEN LIQUID-CHROMATOGRAPHY - SOME THEORETICAL CONSIDERATIONS [J].
KNOX, JH ;
GRANT, IH .
CHROMATOGRAPHIA, 1987, 24 :135-143
[8]   On-line flow sample stacking in a flow injection analysis-capillary electrophoresis system:: 2000-fold enhancement of detection sensitivity for priority phenol pollutants [J].
Kuban, P ;
Berg, M ;
García, C ;
Karlberg, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (01) :163-170
[9]   PHASE-SEPARATION IN SILICA SOL-GEL SYSTEM CONTAINING POLYACRYLIC-ACID .1. GEL FORMATION BEHAVIOR AND EFFECT OF SOLVENT COMPOSITION [J].
NAKANISHI, K ;
SOGA, N .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1992, 139 (01) :1-13
[10]   PHASE-SEPARATION IN SILICA SOL-GEL SYSTEM CONTAINING POLYACRYLIC-ACID .3. EFFECT OF CATALYTIC CONDITION [J].
NAKANISHI, K ;
SOGA, N .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1992, 142 (1-2) :36-44