Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography

被引:104
作者
Hendargo, Hansford C. [1 ]
McNabb, Ryan P. [1 ]
Dhalla, Al-Hafeez [1 ]
Shepherd, Neal [2 ]
Izatt, Joseph A. [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Jean & George Brumley Jr Neonatal Perinatal Res I, Dept Pediat,Div Neonatol, Durham, NC 27710 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 08期
关键词
RETINAL BLOOD-FLOW; IN-VIVO; PHASE MICROSCOPY; MOTION ARTIFACTS; ANGIOGRAPHY; CONTRAST; MICROVASCULATURE; VISUALIZATION; VESSELS;
D O I
10.1364/BOE.2.002175
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent advances in Doppler techniques have enabled high sensitivity imaging of biological flow to measure blood velocities and vascular perfusion. Here we compare spectrometer-based and wavelength-swept Doppler OCT implementations theoretically and experimentally, characterizing the lower and upper observable velocity limits in each configuration. We specifically characterize the washout limit for Doppler OCT, the velocity at which signal degradation results in loss of flow information, which is valid for both quantitative and qualitative flow imaging techniques. We also clearly differentiate the washout effect from the separate phenomenon of phase wrapping. We demonstrate that the maximum detectable Doppler velocity is determined by the fringe washout limit and not phase wrapping. Both theory and experimental results from phantom flow data and retinal blood flow data demonstrate the superiority of the swept-source technique for imaging vessels with high flow rates. (C) 2011 Optical Society of America
引用
收藏
页码:2175 / 2188
页数:14
相关论文
共 49 条
[1]   Resonant Doppler flow imaging and optical vivisection of retinal blood vessels [J].
Bachmann, Adrian H. ;
Villiger, Martin L. ;
Blatter, Cedric ;
Lasser, Theo ;
Leitgeb, Rainer A. .
OPTICS EXPRESS, 2007, 15 (02) :408-422
[2]   Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT [J].
Baumann, Bernhard ;
Potsaid, Benjamin ;
Kraus, Martin F. ;
Liu, Jonathan J. ;
Huang, David ;
Hornegger, Joachim ;
Cable, Alex E. ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1539-1552
[3]   STEADY ENTRY FLOW IN A CURVED PIPE [J].
BOVENDEERD, PHM ;
VANSTEENHOVEN, AA ;
VANDEVOSSE, FN ;
VOSSERS, G .
JOURNAL OF FLUID MECHANICS, 1987, 177 :233-246
[4]   Real-time spectral domain Doppler optical coherence tomography and investigation of human retinal vessel autoregulation [J].
Bower, Bradley A. ;
Zhao, Mingtao ;
Zawadzki, Robert J. ;
Izatt, Joseph A. .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
[5]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[6]   Spectral-domain phase microscopy [J].
Choma, MA ;
Ellerbee, AK ;
Yang, CH ;
Creazzo, TL ;
Izatt, JA .
OPTICS LETTERS, 2005, 30 (10) :1162-1164
[7]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]   Doppler flow imaging of cytoplasmic streaming using spectral domain phase microscopy [J].
Choma, Michael A. ;
Ellerbee, Audrey K. ;
Yazdanfar, Siavash ;
Izatt, Joseph A. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
[9]   THE NEAR INFRARED ABSORPTION SPECTRUM OF LIQUID WATER [J].
CURCIO, JA ;
PETTY, CC .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (05) :302-304
[10]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069