Automated cell count in flow cytometry -: A valuable tool to assess CD4 absolute levels in peripheral blood

被引:13
作者
Béné, MC
Sarda, MNK
El Kaissouni, J
Kennel, AD
Molé, C
Kohler, C
Faure, GC
机构
[1] Fac Med Vandoeuvre Nancy, Immunol Lab, F-54500 Vandoeuvre Nancy, France
[2] CHU Nancy, Vandoeuvre Nancy, France
关键词
flow cytometry; lymphocytes; automated count; HIV;
D O I
10.1093/ajcp/110.3.321
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The enumeration of lymphocyte subsets in absolute counts has long relied on, different methods applied separately to whole blood cell count, lymphocyte differential appreciation, and flow cytometric evaluation of lymphocyte subsets percentages. The development of multicolor labeling methods inflow cytometry now allows a more homogeneous appreciation of several cell subsets among gated lymphocytes. The use of internal calibrators, such as microbead suspensions, also permits a direct appreciation of subsets in absolute counts in a single-platform method. These methods were compared with a traditional multiplatform method of assessing absolute counts of lymphocyte subsets in a pilot study in which all manipulations were performed by 1 person and in a full-scale larger study performed in the normal working conditions of a hospital laboratory. Microspheres seem to be a reliable tool to perform absolute count enumeration inflow cytometry, but several precautions in the sample preparation and flow cytometric analysis are required.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 13 条
[1]   LYMPHOCYTE SUBSET ANALYSIS BY FLOW-CYTOMETRY - COMPARISON OF 3 DIFFERENT STAINING TECHNIQUES AND EFFECTS OF BLOOD-STORAGE [J].
ASHMORE, LM ;
SHOPP, GM ;
EDWARDS, BS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 118 (02) :209-215
[2]  
BENTLEY SA, 1990, CLIN HAEMATOL, V3, P851
[3]   A RAPID, NO-WASH TECHNIQUE FOR IMMUNOPHENOTYPIC ANALYSIS BY FLOW-CYTOMETRY [J].
CALDWELL, CW ;
TAYLOR, HM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1986, 86 (05) :600-607
[4]   GUIDELINE FOR FLOW CYTOMETRIC IMMUNOPHENOTYPING - A REPORT FROM THE NATIONAL-INSTITUTE-OF-ALLERGY-AND-INFECTIOUS-DISEASES, DIVISION OF AIDS [J].
CALVELLI, T ;
DENNY, TN ;
PAXTON, H ;
GELMAN, R ;
KAGAN, J .
CYTOMETRY, 1993, 14 (07) :702-715
[5]  
*CDCP, 1997, MMWR-MORBID MORTAL W, V46, P1
[6]   A COMPARISON OF THE COULTER STKS, COULTER S+IV, AND MANUAL ANALYSIS OF WHITE BLOOD-CELL DIFFERENTIAL COUNTS IN A HUMAN IMMUNODEFICIENCY VIRUS-INFECTED POPULATION [J].
COHEN, AJ ;
PEERSCHKE, EIB ;
STEIGBIGEL, RT .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (06) :611-617
[7]   QUALITY-CONTROL IN THE FLOW CYTOMETRIC MEASUREMENT OF LYMPHOCYTE-T SUBSETS - THE MULTICENTER AIDS COHORT STUDY EXPERIENCE [J].
GIORGI, JV ;
CHENG, HL ;
MARGOLICK, JB ;
BAUER, KD ;
FERBAS, J ;
WAXDAL, M ;
SCHMID, I ;
HULTIN, LE ;
JACKSON, AL ;
PARK, L ;
TAYLOR, JMG .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1990, 55 (02) :173-186
[8]   A SIMULTANEOUS 3-COLOR T-CELL SUBSETS ANALYSIS WITH SINGLE LASER FLOW CYTOMETERS USING T-CELL GATING PROTOCOL - COMPARISON WITH CONVENTIONAL 2-COLOR IMMUNOPHENOTYPING METHOD [J].
MANDY, FF ;
BERGERON, M ;
RECKTENWALD, D ;
IZAGUIRRE, CA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 156 (02) :151-162
[9]   A RAPID TECHNIQUE FOR LYMPHOCYTE PREPARATION PRIOR TO 2-COLOR IMMUNOFLUORESCENCE ANALYSIS OF LYMPHOCYTE SUBSETS USING FLOW-CYTOMETRY - COMPARISON WITH DENSITY GRADIENT SEPARATION [J].
MANSOUR, I ;
BOURIN, P ;
ROUGER, P ;
DOINEL, C .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 127 (01) :61-70
[10]   CD4 T-LYMPHOCYTE DETERMINATIONS ON WHOLE-BLOOD SPECIMENS USING A SINGLE-TUBE 3-COLOR ASSAY [J].
NICHOLSON, JKA ;
JONES, BM ;
HUBBARD, M .
CYTOMETRY, 1993, 14 (06) :685-689