Implantation of a closed-loop stimulation in the management of medically refractory focal epilepsy - A technical note

被引:91
作者
Fountas, KN
Smith, JR
Murro, AM
Politsky, J
Park, YD
Jenkins, PD
机构
[1] Med Coll Georgia, Dept Neurosurg, Augusta, GA 30912 USA
[2] Med Coll Georgia, Dept Neurol, Augusta, GA 30912 USA
关键词
closed-loop stimulation; epilepsy; responsive neurostimulation system; electrocortigrams;
D O I
10.1159/000088656
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Open-loop stimulation studies have shown varying control of seizures with stimulation of different anatomical targets. A recent multi-institutional clinical study utilizing an external closed-loop stimulation system had promising results. A novel implantable closed-loop Responsive Neurostimulation System (RNS) ( Neuropace, Inc., Mountainview, Calif., USA) consisting of a cranially implanted pulse generator, one or two quadripolar subdural strip or depth leads and a programmer is under testing in a prospective clinical trial. The RNS pulse generator continuously analyzes the patient's electrocortigrams (ECoGs) and automatically triggers electrical stimulation when specific ECoG characteristics programmed by the clinician, as indicative of electrographic seizures or precursor of epileptiform activities, are detected. The pulse generator then stores diagnostic information detailing detections and stimulations, including multichannel stored ECoGs. The RNS programmer communicates transcutaneously with the implanted pulse generator when initiated by a clinician. The RNS programmer can download diagnostics and store ECoGs for review. The RNS programmer can then be used to program detection and stimulation parameters. In our current communication, we describe the selection criteria for implanting this system, the preparation of the surgical candidates as well as the surgical technique. We also present our preliminary results with 8 patients who had an RNS implanted. Seven patients (87.5%) had more than 45% decrease in their seizure frequency. The mean follow-up time in our series was 9.2 months. The implantation of a closed-loop stimulation system, in our experience, represents a safe and relatively simple surgical procedure. However, the efficacy of this new treatment modality remains to be determined in further multi-institutional, prospective clinical studies. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 28 条
[1]  
[Anonymous], 2001, Proceedings of the 23rd Annual International Conference of the IEEE
[2]  
BENABID AL, 2004, DEEP BRAIN STIMULATI, P335
[3]   Electrophysiological effects and clinical results of direct brain stimulation for intractable epilepsy [J].
Chkhenkeli, SA ;
Sramka, M ;
Lortkipanidze, GS ;
Rakviashvili, TN ;
Bregvadze, ES ;
Magalashvili, GE ;
Gagoshidze, TS ;
Chkhenkeli, IS .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2004, 106 (04) :318-329
[4]  
Cooper I S, 1978, Electroencephalogr Clin Neurophysiol Suppl, P349
[5]   CHRONIC CEREBELLAR STIMULATION IN EPILEPSY [J].
COOPER, IS ;
AMIN, I ;
RIKLAN, M ;
WALTZ, JM ;
POON, TP .
ARCHIVES OF NEUROLOGY, 1976, 33 (08) :559-570
[6]  
COOPER IS, 1980, APPL NEUROPHYSIOL, V43, P244
[7]   PLACEBO-CONTROLLED PILOT-STUDY OF CENTROMEDIAN THALAMIC-STIMULATION IN TREATMENT OF INTRACTABLE SEIZURES [J].
FISHER, RS ;
UEMATSU, S ;
KRAUSS, GL ;
CYSYK, BJ ;
MCPHERSON, R ;
LESER, RP ;
GORDON, B ;
SCHWERDT, P ;
RISE, M .
EPILEPSIA, 1992, 33 (05) :841-851
[8]   Chronic anterior thalamus stimulation for intractable epilepsy [J].
Hodaie, M ;
Wennberg, RA ;
Dostrovsky, JO ;
Lozano, AM .
EPILEPSIA, 2002, 43 (06) :603-608
[9]   Electrical stimulation of the anterior nucleus of the thalamus for the treatment of intractable epilepsy [J].
Kerrigan, JF ;
Litt, B ;
Fisher, RS ;
Cranstoun, S ;
French, JA ;
Blum, DE ;
Dichter, M ;
Shetter, A ;
Baltuch, G ;
Jaggi, J ;
Krone, S ;
Brodie, M ;
Rise, M ;
Graves, N .
EPILEPSIA, 2004, 45 (04) :346-354
[10]   Electric stimulation on human cortex suppresses fast cortical activity and epileptic spikes [J].
Kinoshita, M ;
Ikeda, A ;
Matsumoto, R ;
Begum, T ;
Usui, K ;
Yamamoto, J ;
Matsuhashi, M ;
Takayama, M ;
Mikuni, N ;
Takahashi, J ;
Miyamoto, S ;
Shibasaki, H .
EPILEPSIA, 2004, 45 (07) :787-791