Study of high- and low-work-function surfaces for hyperthermal surface ionization using an absolute Kelvin probe

被引:27
作者
Baikie, ID [1 ]
Peterman, U [1 ]
Lägel, B [1 ]
Dirscherl, K [1 ]
机构
[1] Robert Gordon Univ, Dept Appl Phys, Aberdeen AB25 1HG, Scotland
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS | 2001年 / 19卷 / 04期
关键词
D O I
10.1116/1.1376701
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We have performed a study of high- (>6 eV) and low- (<3 eV) work-function surfaces in order to identify suitable target materials as an ion source for a new type of mass spectrometer technique based on hyperthermal surface ionization (HSI). In this application a molecular beam of neutral gas molecules is ionized by supersonic collision on a target surface. High-work-function surfaces produce positive ions (pHSI), and low-work-function surfaces negative ions (nHSI). Analytical merits of HSI include very high sensitivity, atmospheric pressure inlet, and informative mass spectra. As this technique does not use electron-impact filaments, the amount of cracking products is substantially reduced. The ultra-high-vacuum (UHV) scanning Kelvin probe is a technique producing relative work-function topographies between a scanning reference tip and the sample in a truly noninvasive fashion with high accuracy (1-2 meV). We demonstrate a novel extension of this technique, using photoelectric determination, which produces absolute work-function data even if the tip work function is not known. Using this hybrid probe, together with scanning electron microscopy and Auger electron spectroscopy, we have followed (a) work-function topographies of clean surfaces in UHV, (b) changes in work function with oxidation that are related to surface cleaning processes, (c) the temperature-dependent oxidation kinetics of polycrystalline metal surfaces (Re, Pt, Mo, W, and Pd) for pHSI, and (d) the stability of Ca, Gd, and LaB6 under residual gases for nHSI. We will report the optimum parameters for target stability and performance under both pHSI and nHSI operating conditions. We will also illustrate informative mass spectra produced by time-of-flight HSI. (C) 2001 American Vacuum Society.
引用
收藏
页码:1460 / 1466
页数:7
相关论文
共 21 条
[1]   NOISE AND THE KELVIN METHOD [J].
BAIKIE, ID ;
MACKENZIE, S ;
ESTRUP, PJZ ;
MEYER, JA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (05) :1326-1332
[2]  
BAIKIE ID, 1991, MATER RES SOC SYMP P, V204, P363
[3]   In situ work function study of oxidation and thin film growth on clean surfaces [J].
Baikie, ID ;
Petermann, U ;
Lägel, B .
SURFACE SCIENCE, 1999, 433 :770-774
[4]   AUTOMATIC KELVIN PROBE COMPATIBLE WITH ULTRAHIGH-VACUUM [J].
BAIKIE, ID ;
VANDERWERF, KO ;
OERBEKKE, H ;
BROEZE, J ;
VANSILFHOUT, A .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (05) :930-934
[5]   Multitip scanning bio-Kelvin probe [J].
Baikie, ID ;
Smith, PJS ;
Porterfield, DM ;
Estrup, PJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03) :1842-1850
[6]  
BAIKIE ID, 1993, MATER RES SOC SYMP P, V309, P35, DOI 10.1557/PROC-309-35
[7]   Surface ionization mass spectrometry of drugs in the thermal and hyperthermal energy range - A comparative study [J].
Dagan, S ;
Amirav, A ;
Fuju, T .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 151 (2-3) :159-165
[8]   HYPERTHERMAL SURFACE-IONIZATION - A NOVEL ION-SOURCE WITH ANALYTICAL APPLICATIONS [J].
DANON, A ;
AMIRAV, A .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 96 (02) :139-167
[9]  
DANON A, 1989, ISRAEL J CHEM, V29, P443
[10]   The analysis of photoelectric sensitivity curves for clean metals at various temperatures [J].
Fowler, RH .