Cord blood levels of interleukin-6 and interleukin-8 for the immediate diagnosis of early-onset infection in premature infants

被引:67
作者
Krueger, M
Nauck, MS
Sang, S
Hentschel, R
Wieland, H
Berner, R
机构
[1] Univ Childrens Hosp, Freiburg, Germany
[2] Univ Freiburg, Dept Clin Chem, Freiburg, Germany
来源
BIOLOGY OF THE NEONATE | 2001年 / 80卷 / 02期
关键词
neonatal sepsis; cytokine; random access chemiluminescence;
D O I
10.1159/000047130
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background. Cytokine plasma levels are suggested to be sensitive indicators of neonatal sepsis, but conventional assays are time consuming. This study aimed at evaluating the significance of cord blood levels of interleukin (IL)-6 and IL-8 determined by a fully automated random access assay within 90 min of admission to predict systemic bacterial infection. Patients and Methods: Cord blood levels of IL-6 and IL-8 were determined in 71 mature and 100 premature infants by a chemiluminescence assay (Immulite (R)). Patients were divided into four groups according to a clinical and laboratory scoring system. Group A: documented early-onset infection; group B: infection possible; group C: infection unlikely, and group D: healthy newborns. Results: Median IL-6 levels in the subgroup of premature newborns were as follows: group A, 1,920 pg/ml (5-95% confidence interval 308-4,660 pg/ml); group B, 50 (15-102) pg/ml; group C, 21 (12-71) pg/ml, and group D, 8 (6-11) pg/ml. For IL-8, median levels for groups A-D were 289 (226-514) pg/ml, 87 (40-107) pg/ml, 44 (33-98) pg/ml and 21 (16-25) pg/ml, respectively. The difference between group A and the other groups was highly significant (IL-6 p < 0.0001, IL-8 p < 0.001). At a cut-off of 80 pg/ml, the sensitivity of IL-6 for the diagnosis of sepsis was 96% (specificity 95%). For IL-8 (cut-off 90 pg/ml), the sensitivity was 87% (specificity 94%). Conclusion: In premature infants, the diagnosis of an early-onset infection can be established or ruled out with a high level of confidence by measuring IL-6 or IL-8 levels from cord blood using a random access chemiluminescence assay. Copyright (C) 2001 S. Karger AG, Basel.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 39 条
[1]  
BABSON AL, 1991, J CLIN IMMUNOASSAY, V14, P83
[2]   NEUTROPHIL-ACTIVATING PEPTIDE-1 INTERLEUKIN-8, A NOVEL CYTOKINE THAT ACTIVATES NEUTROPHILS [J].
BAGGIOLINI, M ;
WALZ, A ;
KUNKEL, SL .
JOURNAL OF CLINICAL INVESTIGATION, 1989, 84 (04) :1045-1049
[3]   Plasma levels and gene expression of granulocyte colony-stimulating factor, tumor necrosis factor-α, interleukin (IL)-1β, IL-6, IL-8, and soluble intercellular adhesion molecule-1 in neonatal early onset sepsis [J].
Berner, R ;
Niemeyer, CM ;
Leititis, JU ;
Funke, A ;
Schwab, C ;
Rau, U ;
Richter, K ;
Tawfeek, MSK ;
Clad, A ;
Brandis, M .
PEDIATRIC RESEARCH, 1998, 44 (04) :469-477
[4]   Low prevalence of the immunoglobulin-A-binding β antigen of the C protein among Streptococcus agalactiae isolates causing neonatal sepsis [J].
Berner, R ;
Bender, A ;
Rensing, C ;
Forster, J ;
Brandis, M .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (08) :545-550
[5]  
BERNER R, 2000, EUR J PEDIATR, V159, P71
[6]   CIRCULATING INTERLEUKIN-6 DURING A CONTINUOUS INFUSION OF TUMOR NECROSIS FACTOR AND INTERFERON-GAMMA [J].
BROUCKAERT, P ;
SPRIGGS, DR ;
DEMETRI, G ;
KUFE, DW ;
FIERS, W .
JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 169 (06) :2257-2262
[7]  
BUCK C, 1994, PEDIATRICS, V93, P54
[8]   HIGH CIRCULATING LEVELS OF INTERLEUKIN-6 IN PATIENTS WITH SEPTIC SHOCK - EVOLUTION DURING SEPSIS, PROGNOSTIC VALUE, AND INTERPLAY WITH OTHER CYTOKINES [J].
CALANDRA, T ;
GERAIN, J ;
HEUMANN, D ;
BAUMGARTNER, JD ;
GLAUSER, MP .
AMERICAN JOURNAL OF MEDICINE, 1991, 91 (01) :23-29
[9]   PLASMA-CLEARANCE, ORGAN DISTRIBUTION AND TARGET-CELLS OF INTERLEUKIN-6 HEPATOCYTE-STIMULATING FACTOR IN THE RAT [J].
CASTELL, JV ;
GEIGER, T ;
GROSS, V ;
ANDUS, T ;
WALTER, E ;
HIRANO, T ;
KISHIMOTO, T ;
HEINRICH, PC .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1988, 177 (02) :357-361
[10]  
DEBONT ESJM, 1994, ACTA PAEDIATR, V83, P696